Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon

A separation for Cd2+ and its interferences of common cations (Na+, NH+, K+, Mg2+, and Ca2+) was performed. Cation-exchange ion chromatography for Cd2+ and common cations separation on a weakly acidic H+ forming cation-exchange resin was investigated and applied to test the efficacy of activated car...

Full description

Saved in:
Bibliographic Details
Main Authors: Musa, Mutah, Kikuchi, Akira, Ismail, Nor Eman, Jaafar, Jafariah, Abdul Majid, Zaiton, Salim, Mohd. Razman, Tanaka, Kazuhiko
Format: Article
Published: Taylor and Francis Inc. 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/51897/
http://dx.doi.org/10.1080/19443994.2013.854099
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.51897
record_format eprints
spelling my.utm.518972018-11-09T08:29:44Z http://eprints.utm.my/id/eprint/51897/ Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon Musa, Mutah Kikuchi, Akira Ismail, Nor Eman Jaafar, Jafariah Abdul Majid, Zaiton Salim, Mohd. Razman Tanaka, Kazuhiko TA Engineering (General). Civil engineering (General) A separation for Cd2+ and its interferences of common cations (Na+, NH+, K+, Mg2+, and Ca2+) was performed. Cation-exchange ion chromatography for Cd2+ and common cations separation on a weakly acidic H+ forming cation-exchange resin was investigated and applied to test the efficacy of activated carbon in the removal of Cd2+ from simulated wastewater. The difference of retention volumes between Ca2+ and Cd2+ was 0.45 mL for oxalic acid with a concentration of 1.75 mM, and the retention volume drastically decreased when the oxalic acid concentration increased in the eluent. Considering the prevailing conditions for TOSOH TSK gel Super IC A/C at 40°C with a least pH limit of 2.0, 1.75 mM of oxalic acid was selected for rapid analysis with pH of 2.3. Applying 50 μL sample injection, the calibration curve was linear for tested standard samples ranging from 0.05 to 2.0 mg/L, the detection limit (S/N = 3) was 0.066 mg/L (0.583 μM), and the analysis was applicable with coexisting Ca2+ up to 10.0 mg/L (250 μM) while other cations did not interfere. It was possible to analyze three samples within an hour. The application of this method on Cd2+ adsorption indicated the effectiveness of the method for heavy metals' analysis. Taylor and Francis Inc. 2014 Article PeerReviewed Musa, Mutah and Kikuchi, Akira and Ismail, Nor Eman and Jaafar, Jafariah and Abdul Majid, Zaiton and Salim, Mohd. Razman and Tanaka, Kazuhiko (2014) Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon. Desalination and Water Treatment, 52 (19-21). pp. 3616-3622. ISSN 1944-3986 http://dx.doi.org/10.1080/19443994.2013.854099
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Musa, Mutah
Kikuchi, Akira
Ismail, Nor Eman
Jaafar, Jafariah
Abdul Majid, Zaiton
Salim, Mohd. Razman
Tanaka, Kazuhiko
Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon
description A separation for Cd2+ and its interferences of common cations (Na+, NH+, K+, Mg2+, and Ca2+) was performed. Cation-exchange ion chromatography for Cd2+ and common cations separation on a weakly acidic H+ forming cation-exchange resin was investigated and applied to test the efficacy of activated carbon in the removal of Cd2+ from simulated wastewater. The difference of retention volumes between Ca2+ and Cd2+ was 0.45 mL for oxalic acid with a concentration of 1.75 mM, and the retention volume drastically decreased when the oxalic acid concentration increased in the eluent. Considering the prevailing conditions for TOSOH TSK gel Super IC A/C at 40°C with a least pH limit of 2.0, 1.75 mM of oxalic acid was selected for rapid analysis with pH of 2.3. Applying 50 μL sample injection, the calibration curve was linear for tested standard samples ranging from 0.05 to 2.0 mg/L, the detection limit (S/N = 3) was 0.066 mg/L (0.583 μM), and the analysis was applicable with coexisting Ca2+ up to 10.0 mg/L (250 μM) while other cations did not interfere. It was possible to analyze three samples within an hour. The application of this method on Cd2+ adsorption indicated the effectiveness of the method for heavy metals' analysis.
format Article
author Musa, Mutah
Kikuchi, Akira
Ismail, Nor Eman
Jaafar, Jafariah
Abdul Majid, Zaiton
Salim, Mohd. Razman
Tanaka, Kazuhiko
author_facet Musa, Mutah
Kikuchi, Akira
Ismail, Nor Eman
Jaafar, Jafariah
Abdul Majid, Zaiton
Salim, Mohd. Razman
Tanaka, Kazuhiko
author_sort Musa, Mutah
title Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon
title_short Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon
title_full Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon
title_fullStr Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon
title_full_unstemmed Application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon
title_sort application of ion chromatography for the assessment of cadmium adsorption in simulated wastewater by activated carbon
publisher Taylor and Francis Inc.
publishDate 2014
url http://eprints.utm.my/id/eprint/51897/
http://dx.doi.org/10.1080/19443994.2013.854099
_version_ 1643653094442008576
score 13.211869