Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition

The presence of the vortex formation associated with high pressure gradient has aggravated the rupture at the aneurismal wall. In order to decrease the possibility of aneurysm to be rupture, device like wire-mesh called stent was inserted at the aneurysm bulge. This study was focused on investigates...

Full description

Saved in:
Bibliographic Details
Main Authors: Taib, I., Osman, K., Hermawan, H., Abd. Kadir, M. R.
Format: Conference or Workshop Item
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/51256/
http://dx.doi.org/10.4028/www.scientific.net/AMM.388.29
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.51256
record_format eprints
spelling my.utm.512562017-09-18T00:35:28Z http://eprints.utm.my/id/eprint/51256/ Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition Taib, I. Osman, K. Hermawan, H. Abd. Kadir, M. R. QH Natural history The presence of the vortex formation associated with high pressure gradient has aggravated the rupture at the aneurismal wall. In order to decrease the possibility of aneurysm to be rupture, device like wire-mesh called stent was inserted at the aneurysm bulge. This study was focused on investigates the hemodynamic factor especially pressure distribution toward the failure of the aneurismal wall. Computational fluid dynamics method has used to identify the influence of the hemodynamic factor at the aneurysm. The results of this study shown the slightly decrease of the pressure distribution after the insertion of the bare metallic stent (BMS). The results on non-stented aneurysm was depicted the strong vortex was dominated the entire region of aneurysm. The strength of the vortex also was seems very weak after the insertion of this stent. The flow visualization between stented and non-stented aneurysm has given a good features in deep understanding of hemodynamic effect on the aneurismal wall. From the observed, the insertion of the stent manages to reduce the stress that exerted to aneurismal wall as well as decreased the strength of the vortex formation. 2013 Conference or Workshop Item PeerReviewed Taib, I. and Osman, K. and Hermawan, H. and Abd. Kadir, M. R. (2013) Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition. In: Applied Mechanics And Materials. http://dx.doi.org/10.4028/www.scientific.net/AMM.388.29
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QH Natural history
spellingShingle QH Natural history
Taib, I.
Osman, K.
Hermawan, H.
Abd. Kadir, M. R.
Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition
description The presence of the vortex formation associated with high pressure gradient has aggravated the rupture at the aneurismal wall. In order to decrease the possibility of aneurysm to be rupture, device like wire-mesh called stent was inserted at the aneurysm bulge. This study was focused on investigates the hemodynamic factor especially pressure distribution toward the failure of the aneurismal wall. Computational fluid dynamics method has used to identify the influence of the hemodynamic factor at the aneurysm. The results of this study shown the slightly decrease of the pressure distribution after the insertion of the bare metallic stent (BMS). The results on non-stented aneurysm was depicted the strong vortex was dominated the entire region of aneurysm. The strength of the vortex also was seems very weak after the insertion of this stent. The flow visualization between stented and non-stented aneurysm has given a good features in deep understanding of hemodynamic effect on the aneurismal wall. From the observed, the insertion of the stent manages to reduce the stress that exerted to aneurismal wall as well as decreased the strength of the vortex formation.
format Conference or Workshop Item
author Taib, I.
Osman, K.
Hermawan, H.
Abd. Kadir, M. R.
author_facet Taib, I.
Osman, K.
Hermawan, H.
Abd. Kadir, M. R.
author_sort Taib, I.
title Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition
title_short Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition
title_full Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition
title_fullStr Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition
title_full_unstemmed Preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition
title_sort preliminary study on the comparable flow pattern between stented and non-stented aneurysm at hypertension condition
publishDate 2013
url http://eprints.utm.my/id/eprint/51256/
http://dx.doi.org/10.4028/www.scientific.net/AMM.388.29
_version_ 1643652986108379136