Experimental investigation of retrofitted extended end-plate connections

A series of retrofitted extended end-plate connections have been tested experimentally and evaluated using the component method specified in Eurocode 3. The component method decomposed the end-plate connection into several components, including the tension zone, compression zone, vertical and horizo...

Full description

Saved in:
Bibliographic Details
Main Authors: Shek, Poingian, Tahir, Mahmood Md Md, Tan, Chersiang, Sulaiman, Arizu
Format: Conference or Workshop Item
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/51054/
http://dx.doi.org/10.4028/www.scientific.net/AMM.284-287.1330
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.51054
record_format eprints
spelling my.utm.510542017-07-12T04:05:32Z http://eprints.utm.my/id/eprint/51054/ Experimental investigation of retrofitted extended end-plate connections Shek, Poingian Tahir, Mahmood Md Md Tan, Chersiang Sulaiman, Arizu TA Engineering (General). Civil engineering (General) A series of retrofitted extended end-plate connections have been tested experimentally and evaluated using the component method specified in Eurocode 3. The component method decomposed the end-plate connection into several components, including the tension zone, compression zone, vertical and horizontal shear zone that occurred at the bolt, end-plate, beam and column. Based on the theoretical model, the moment resistance and the initial stiffness of a connection can be predicted. Four experimental tests on the retrofitted extended end-plate connections have been conducted to verify the proposed design method. From the experiment tests, all moment resistance of the connections showed good agreement with theoretical predictions, which establish a reliable foundation to predict the moment resistance of the retrofitted end-plate connection. All initial stiffnesses calculated from theoretical predictions do not represent the actual behaviour of tested connection. All tested connections can be classified as partial strength based on EC 3: Part 1.8, in condition the welding capacity is at least 50% higher than the capacity calculated from the component method. © (2013) Trans Tech Publications, Switzerland. 2013 Conference or Workshop Item PeerReviewed Shek, Poingian and Tahir, Mahmood Md Md and Tan, Chersiang and Sulaiman, Arizu (2013) Experimental investigation of retrofitted extended end-plate connections. In: 2nd International Conference on Engineering and Technology Innovation 2012, ICETI 2012, 2-6 November 2012, Kaohsiung; Taiwan. http://dx.doi.org/10.4028/www.scientific.net/AMM.284-287.1330
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Shek, Poingian
Tahir, Mahmood Md Md
Tan, Chersiang
Sulaiman, Arizu
Experimental investigation of retrofitted extended end-plate connections
description A series of retrofitted extended end-plate connections have been tested experimentally and evaluated using the component method specified in Eurocode 3. The component method decomposed the end-plate connection into several components, including the tension zone, compression zone, vertical and horizontal shear zone that occurred at the bolt, end-plate, beam and column. Based on the theoretical model, the moment resistance and the initial stiffness of a connection can be predicted. Four experimental tests on the retrofitted extended end-plate connections have been conducted to verify the proposed design method. From the experiment tests, all moment resistance of the connections showed good agreement with theoretical predictions, which establish a reliable foundation to predict the moment resistance of the retrofitted end-plate connection. All initial stiffnesses calculated from theoretical predictions do not represent the actual behaviour of tested connection. All tested connections can be classified as partial strength based on EC 3: Part 1.8, in condition the welding capacity is at least 50% higher than the capacity calculated from the component method. © (2013) Trans Tech Publications, Switzerland.
format Conference or Workshop Item
author Shek, Poingian
Tahir, Mahmood Md Md
Tan, Chersiang
Sulaiman, Arizu
author_facet Shek, Poingian
Tahir, Mahmood Md Md
Tan, Chersiang
Sulaiman, Arizu
author_sort Shek, Poingian
title Experimental investigation of retrofitted extended end-plate connections
title_short Experimental investigation of retrofitted extended end-plate connections
title_full Experimental investigation of retrofitted extended end-plate connections
title_fullStr Experimental investigation of retrofitted extended end-plate connections
title_full_unstemmed Experimental investigation of retrofitted extended end-plate connections
title_sort experimental investigation of retrofitted extended end-plate connections
publishDate 2013
url http://eprints.utm.my/id/eprint/51054/
http://dx.doi.org/10.4028/www.scientific.net/AMM.284-287.1330
_version_ 1643652925308796928