Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography

The needs of accurate information from tomography images has led to the exploration of 3D imaging which attracts both medical field and industrial process as 3D imaging technique provides additional info compared to 2D. The same thing goes to Magnetic Induction Tomography (MIT) even 3D is still new...

Full description

Saved in:
Bibliographic Details
Main Authors: Zakaria, Z., Balkhis, I., Yaacob, S., Mansor, M. S. B., Rahim, R. A., Rahim, H. A.
Format: Conference or Workshop Item
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/51050/
http://dx.doi.org/10.1109/UKSim.2013.18
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.51050
record_format eprints
spelling my.utm.510502017-09-17T06:20:06Z http://eprints.utm.my/id/eprint/51050/ Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography Zakaria, Z. Balkhis, I. Yaacob, S. Mansor, M. S. B. Rahim, R. A. Rahim, H. A. T Technology The needs of accurate information from tomography images has led to the exploration of 3D imaging which attracts both medical field and industrial process as 3D imaging technique provides additional info compared to 2D. The same thing goes to Magnetic Induction Tomography (MIT) even 3D is still new to this modality. The challenge of 3D scheme to MIT is that the sensitivity at the boundary is more pronounce compared the centre of region of interest (ROI). The introduction of tri-coil sensor jig offers solution to this issue as three layers of sensors are located in this design, with excitation coils arranged at the middle layer. This arrangement strengthened the sensitivity at the centre of the z-axis between upper and lower layer through the existing of middle layer. This paper would like to discuss on the sensitivity of the z-axis of tri-coil sensor jig from the scope of metal imaging application. The simulation result has found that all the three coils are sensitive to the metal object at different z-positions. This result provides additional info as it will be integrated in the 3D image reconstruction algorithm process for providing accurate location of the 3D reconstructed images. 2013 Conference or Workshop Item PeerReviewed Zakaria, Z. and Balkhis, I. and Yaacob, S. and Mansor, M. S. B. and Rahim, R. A. and Rahim, H. A. (2013) Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography. In: Proceedings - UKSim 15th International Conference on Computer Modelling and Simulation, UKSim 2013. http://dx.doi.org/10.1109/UKSim.2013.18
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology
spellingShingle T Technology
Zakaria, Z.
Balkhis, I.
Yaacob, S.
Mansor, M. S. B.
Rahim, R. A.
Rahim, H. A.
Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography
description The needs of accurate information from tomography images has led to the exploration of 3D imaging which attracts both medical field and industrial process as 3D imaging technique provides additional info compared to 2D. The same thing goes to Magnetic Induction Tomography (MIT) even 3D is still new to this modality. The challenge of 3D scheme to MIT is that the sensitivity at the boundary is more pronounce compared the centre of region of interest (ROI). The introduction of tri-coil sensor jig offers solution to this issue as three layers of sensors are located in this design, with excitation coils arranged at the middle layer. This arrangement strengthened the sensitivity at the centre of the z-axis between upper and lower layer through the existing of middle layer. This paper would like to discuss on the sensitivity of the z-axis of tri-coil sensor jig from the scope of metal imaging application. The simulation result has found that all the three coils are sensitive to the metal object at different z-positions. This result provides additional info as it will be integrated in the 3D image reconstruction algorithm process for providing accurate location of the 3D reconstructed images.
format Conference or Workshop Item
author Zakaria, Z.
Balkhis, I.
Yaacob, S.
Mansor, M. S. B.
Rahim, R. A.
Rahim, H. A.
author_facet Zakaria, Z.
Balkhis, I.
Yaacob, S.
Mansor, M. S. B.
Rahim, R. A.
Rahim, H. A.
author_sort Zakaria, Z.
title Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography
title_short Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography
title_full Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography
title_fullStr Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography
title_full_unstemmed Evaluation on the sensitivity of tri-coil sensor jig for 3D image reconstruction in magnetic induction tomography
title_sort evaluation on the sensitivity of tri-coil sensor jig for 3d image reconstruction in magnetic induction tomography
publishDate 2013
url http://eprints.utm.my/id/eprint/51050/
http://dx.doi.org/10.1109/UKSim.2013.18
_version_ 1643652924143828992
score 13.160551