Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography

Suspended solids in the aqueous environment can become carrier of microorganic pollutants, which may lead to the accumulation and give a toxicity impact towards the environment and human health. A suitable methodology for pesticide residue analysis in suspended solid river water sample was investiga...

Full description

Saved in:
Bibliographic Details
Main Author: Abd. Razak, Nur Fadzilah
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/48868/25/NurFadzilahAbdMFS2014.pdf
http://eprints.utm.my/id/eprint/48868/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:86754
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.48868
record_format eprints
spelling my.utm.488682020-07-02T07:42:11Z http://eprints.utm.my/id/eprint/48868/ Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography Abd. Razak, Nur Fadzilah QD Chemistry Suspended solids in the aqueous environment can become carrier of microorganic pollutants, which may lead to the accumulation and give a toxicity impact towards the environment and human health. A suitable methodology for pesticide residue analysis in suspended solid river water sample was investigated in this study based on ultrasonic extraction (USE) and gas chromatography (GC). Sampling was conducted between May 2013 and June 2014 at sampling site from the water intake point of Syarikat Air Johor Water Treatment Plant of Sungai Skudai. Suspended solid were obtained after the river water samples were filtered using reduced cellulose filter membrane and were extracted using USE technique. The presence of organochlorine pesticide (OCPs) which are aldrin, dieldrin and endrin was determined using gas chromatography mass selective detector (GC-MSD). However, the presence of OCPs was not detectable in all the water samples investigated. An alternative approach has been taken by analyzing the samples using liquid chromatography-tandem mass spectrometry (LC-MS-MS). However, the presence of OCPs was still not detectable. Therefore, for quantitative analysis, three selected OCPs were spiked into the sample (50 µg/L) for determination of optimum condition for extraction in suspended solid using USE technique with regards to solvent types and sonication time. The limit of detection of OCPs were from 0.144 to 0.154 µg/L and the optimum condition for extraction of OCPs in suspended solid was by using ethyl acetate as extraction solvent with 30 minutes of extraction time. The recoveries obtained were in the range of 62.4% to 101.8% with RSDs of less than 15%. The green chemistry sample preparation technique and low toxicity solvents employed in this extraction technique are thus recommended for routine environmental monitoring analysis. 2014-08 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/48868/25/NurFadzilahAbdMFS2014.pdf Abd. Razak, Nur Fadzilah (2014) Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography. Masters thesis, Universiti Teknologi Malaysia, Faculty of Science. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:86754
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic QD Chemistry
spellingShingle QD Chemistry
Abd. Razak, Nur Fadzilah
Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography
description Suspended solids in the aqueous environment can become carrier of microorganic pollutants, which may lead to the accumulation and give a toxicity impact towards the environment and human health. A suitable methodology for pesticide residue analysis in suspended solid river water sample was investigated in this study based on ultrasonic extraction (USE) and gas chromatography (GC). Sampling was conducted between May 2013 and June 2014 at sampling site from the water intake point of Syarikat Air Johor Water Treatment Plant of Sungai Skudai. Suspended solid were obtained after the river water samples were filtered using reduced cellulose filter membrane and were extracted using USE technique. The presence of organochlorine pesticide (OCPs) which are aldrin, dieldrin and endrin was determined using gas chromatography mass selective detector (GC-MSD). However, the presence of OCPs was not detectable in all the water samples investigated. An alternative approach has been taken by analyzing the samples using liquid chromatography-tandem mass spectrometry (LC-MS-MS). However, the presence of OCPs was still not detectable. Therefore, for quantitative analysis, three selected OCPs were spiked into the sample (50 µg/L) for determination of optimum condition for extraction in suspended solid using USE technique with regards to solvent types and sonication time. The limit of detection of OCPs were from 0.144 to 0.154 µg/L and the optimum condition for extraction of OCPs in suspended solid was by using ethyl acetate as extraction solvent with 30 minutes of extraction time. The recoveries obtained were in the range of 62.4% to 101.8% with RSDs of less than 15%. The green chemistry sample preparation technique and low toxicity solvents employed in this extraction technique are thus recommended for routine environmental monitoring analysis.
format Thesis
author Abd. Razak, Nur Fadzilah
author_facet Abd. Razak, Nur Fadzilah
author_sort Abd. Razak, Nur Fadzilah
title Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography
title_short Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography
title_full Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography
title_fullStr Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography
title_full_unstemmed Analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography
title_sort analysis of organochlorine pesticides in suspended solid using ultrasonic solvent extraction and gas chromatography
publishDate 2014
url http://eprints.utm.my/id/eprint/48868/25/NurFadzilahAbdMFS2014.pdf
http://eprints.utm.my/id/eprint/48868/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:86754