Neuro-network modelling and control of flexibly mounted cylindrical riser
Rapid development and exploration in deepwater field increase the use of the marine riser. Vortex Induced Vibration (VIV) is a phenomenon where fluid flow cross flow bluff structure and cause vibration. VIV cause fatigue damage and premature failure of the marine riser. In order to extend the life o...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/48809/25/HorWinHanMFM2015.pdf http://eprints.utm.my/id/eprint/48809/ http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:83939 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.48809 |
---|---|
record_format |
eprints |
spelling |
my.utm.488092020-06-24T02:44:29Z http://eprints.utm.my/id/eprint/48809/ Neuro-network modelling and control of flexibly mounted cylindrical riser Hor, Win Han TJ Mechanical engineering and machinery Rapid development and exploration in deepwater field increase the use of the marine riser. Vortex Induced Vibration (VIV) is a phenomenon where fluid flow cross flow bluff structure and cause vibration. VIV cause fatigue damage and premature failure of the marine riser. In order to extend the life of marine riser, there are two categories of method to control vibration, i.e. passive and active vibration control. Passive vibration control is a method where no energy is introduced into the system, devices are added to the vibrating structure and leave it to response to the vibration automatically. Active vibration is a method by introducing energy to the vibration system, devices are installed and energized to react oppose to the vibration. This system required controller to control the device to suit various vibration condition. In this project active vibration suppression model is studied to suppress the Vortex Induced Vibration (VIV). Due to difficulty and complexity of vortex induced vibration mathematic calculation, and hence mathematic modeling of the VIV is replaced by using Neural Network identification technique. Two system identification techniques are use which are NARX and TDNN .Experiment is setup to acquire input/output data for the system identification. Finally, Active Vibration Control strategy is simulated by using the identified system with proper tuning PID controller. The result of the studies showed that NARX performance is superior as compared to TDNN for system identification, whereas TDNN identified model showed better result to suppress vibration amplitude using AVC PID controller. 2015-01 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/48809/25/HorWinHanMFM2015.pdf Hor, Win Han (2015) Neuro-network modelling and control of flexibly mounted cylindrical riser. Masters thesis, Universiti Teknologi Malaysia, Faculty of Mechanical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:83939 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Hor, Win Han Neuro-network modelling and control of flexibly mounted cylindrical riser |
description |
Rapid development and exploration in deepwater field increase the use of the marine riser. Vortex Induced Vibration (VIV) is a phenomenon where fluid flow cross flow bluff structure and cause vibration. VIV cause fatigue damage and premature failure of the marine riser. In order to extend the life of marine riser, there are two categories of method to control vibration, i.e. passive and active vibration control. Passive vibration control is a method where no energy is introduced into the system, devices are added to the vibrating structure and leave it to response to the vibration automatically. Active vibration is a method by introducing energy to the vibration system, devices are installed and energized to react oppose to the vibration. This system required controller to control the device to suit various vibration condition. In this project active vibration suppression model is studied to suppress the Vortex Induced Vibration (VIV). Due to difficulty and complexity of vortex induced vibration mathematic calculation, and hence mathematic modeling of the VIV is replaced by using Neural Network identification technique. Two system identification techniques are use which are NARX and TDNN .Experiment is setup to acquire input/output data for the system identification. Finally, Active Vibration Control strategy is simulated by using the identified system with proper tuning PID controller. The result of the studies showed that NARX performance is superior as compared to TDNN for system identification, whereas TDNN identified model showed better result to suppress vibration amplitude using AVC PID controller. |
format |
Thesis |
author |
Hor, Win Han |
author_facet |
Hor, Win Han |
author_sort |
Hor, Win Han |
title |
Neuro-network modelling and control of flexibly mounted cylindrical riser |
title_short |
Neuro-network modelling and control of flexibly mounted cylindrical riser |
title_full |
Neuro-network modelling and control of flexibly mounted cylindrical riser |
title_fullStr |
Neuro-network modelling and control of flexibly mounted cylindrical riser |
title_full_unstemmed |
Neuro-network modelling and control of flexibly mounted cylindrical riser |
title_sort |
neuro-network modelling and control of flexibly mounted cylindrical riser |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/48809/25/HorWinHanMFM2015.pdf http://eprints.utm.my/id/eprint/48809/ http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:83939 |
_version_ |
1672610470507315200 |
score |
13.214268 |