Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer

High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. PD phenomenon causes...

Full description

Saved in:
Bibliographic Details
Main Author: Hasan, Qusay Othman
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/48799/1/QusayOthmanHasanMFKE2014.pdf
http://eprints.utm.my/id/eprint/48799/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:89207
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.48799
record_format eprints
spelling my.utm.487992020-06-24T02:00:37Z http://eprints.utm.my/id/eprint/48799/ Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer Hasan, Qusay Othman TK Electrical engineering. Electronics Nuclear engineering High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. PD phenomenon causes gradual deterioration of the insulating materials, sometimes over a period of several years, leading perhaps to eventual failure. Detecting PD in power transformers is vital both in industries and utilities to avoid damage of high-voltage equipment. The objectives for this thesis are: To conduct an experiment for the detection of PD using multi-mode optical fiber sensors under high voltage insulation oil conditions .To characterize the Partial discharges through leakage current sensor and signal monitoring in Palm oil insulation. Comparison of optical and conventional (leakage current) and analyze the output in time and frequency domain of the waveform. These data will evaluate in time and frequency domain by using analyzing software program (Origin-Pro). The conclusion that can acquire from this software and from the experimental lap results shown impressive characteristic for the PD detection and recommend the both sensors as a good tools for monitor and assessment the insulation condition when the discharge emission occur. 2014-12 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/48799/1/QusayOthmanHasanMFKE2014.pdf Hasan, Qusay Othman (2014) Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:89207
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Hasan, Qusay Othman
Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer
description High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. PD phenomenon causes gradual deterioration of the insulating materials, sometimes over a period of several years, leading perhaps to eventual failure. Detecting PD in power transformers is vital both in industries and utilities to avoid damage of high-voltage equipment. The objectives for this thesis are: To conduct an experiment for the detection of PD using multi-mode optical fiber sensors under high voltage insulation oil conditions .To characterize the Partial discharges through leakage current sensor and signal monitoring in Palm oil insulation. Comparison of optical and conventional (leakage current) and analyze the output in time and frequency domain of the waveform. These data will evaluate in time and frequency domain by using analyzing software program (Origin-Pro). The conclusion that can acquire from this software and from the experimental lap results shown impressive characteristic for the PD detection and recommend the both sensors as a good tools for monitor and assessment the insulation condition when the discharge emission occur.
format Thesis
author Hasan, Qusay Othman
author_facet Hasan, Qusay Othman
author_sort Hasan, Qusay Othman
title Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer
title_short Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer
title_full Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer
title_fullStr Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer
title_full_unstemmed Partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer
title_sort partial discharge detection using leakage current and optical technique in insulation oil of high voltage transformer
publishDate 2014
url http://eprints.utm.my/id/eprint/48799/1/QusayOthmanHasanMFKE2014.pdf
http://eprints.utm.my/id/eprint/48799/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:89207
_version_ 1672610469207080960
score 13.160551