Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph

Miscible displacements of waterflood residual oil in packed glass beads were carried out. In the experiments, n-hexane was used as solvent to miscibly displaced and recover n-octane, n-decane or mixture of broth. A gas chromatograph model HP 5890A was employed to determine the produced hydrocarbons...

Full description

Saved in:
Bibliographic Details
Main Author: Yunan, Mat Hussin
Format: Article
Language:English
Published: 1989
Subjects:
Online Access:http://eprints.utm.my/id/eprint/4808/1/MatHussinYunan1989_DeterminationOfHydrocarbonsVolumetricFractions.pdf
http://eprints.utm.my/id/eprint/4808/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.4808
record_format eprints
spelling my.utm.48082010-06-01T03:20:56Z http://eprints.utm.my/id/eprint/4808/ Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph Yunan, Mat Hussin T Technology (General) Miscible displacements of waterflood residual oil in packed glass beads were carried out. In the experiments, n-hexane was used as solvent to miscibly displaced and recover n-octane, n-decane or mixture of broth. A gas chromatograph model HP 5890A was employed to determine the produced hydrocarbons volumetric compositions. Samples injection were done manually by 1 uL syringe. Flame Ionization Detector (FID) with helium and hydrogen as carrier gas was used. The gas chromatograph integrator was Shimadzu C-R3A. Initially samples of known volumetric fractions of n-hexane, n-octane and n-decane were prepared. These were injected into the gas chromatograph and the respective peak areas were obtained. The known volumetric frations versus the peak areas obtained from the chromatograms were plotted for each component. These standard curve were later used to determine the volumetric fractions of the produced fluids from the miscible displacements. The reproducibility of the systems was checked four times and found very satisfactory. More than one hundred samples containing mixtures of n-hexane, n-octane and n-decane were analysed. The volume of samples range from 6.0mL to 12 mL. The volumetric fractions and hence the recovery efficiency of the miscible displacements were successfully obtained. 1989 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/4808/1/MatHussinYunan1989_DeterminationOfHydrocarbonsVolumetricFractions.pdf Yunan, Mat Hussin (1989) Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph. Proceedings of The Fifth Symposium Of Malaysian Chemical Engineers . pp. 190-204.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Yunan, Mat Hussin
Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph
description Miscible displacements of waterflood residual oil in packed glass beads were carried out. In the experiments, n-hexane was used as solvent to miscibly displaced and recover n-octane, n-decane or mixture of broth. A gas chromatograph model HP 5890A was employed to determine the produced hydrocarbons volumetric compositions. Samples injection were done manually by 1 uL syringe. Flame Ionization Detector (FID) with helium and hydrogen as carrier gas was used. The gas chromatograph integrator was Shimadzu C-R3A. Initially samples of known volumetric fractions of n-hexane, n-octane and n-decane were prepared. These were injected into the gas chromatograph and the respective peak areas were obtained. The known volumetric frations versus the peak areas obtained from the chromatograms were plotted for each component. These standard curve were later used to determine the volumetric fractions of the produced fluids from the miscible displacements. The reproducibility of the systems was checked four times and found very satisfactory. More than one hundred samples containing mixtures of n-hexane, n-octane and n-decane were analysed. The volume of samples range from 6.0mL to 12 mL. The volumetric fractions and hence the recovery efficiency of the miscible displacements were successfully obtained.
format Article
author Yunan, Mat Hussin
author_facet Yunan, Mat Hussin
author_sort Yunan, Mat Hussin
title Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph
title_short Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph
title_full Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph
title_fullStr Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph
title_full_unstemmed Determination of hydrocarbons volumetric fractions by a HP 5890A gas chromatograph
title_sort determination of hydrocarbons volumetric fractions by a hp 5890a gas chromatograph
publishDate 1989
url http://eprints.utm.my/id/eprint/4808/1/MatHussinYunan1989_DeterminationOfHydrocarbonsVolumetricFractions.pdf
http://eprints.utm.my/id/eprint/4808/
_version_ 1643644153407471616
score 13.160551