Push tests on innovative shear connector for composite beam with cold-formed steel section

In this study, experimental tests were conducted to investigate the ductility and strength capacity of new shear connector. Push test specimens were prepared and tested according to EN1994-1-1 standard. The push test specimen consists of two cold-formed steel lipped channel sections oriented back-to...

Full description

Saved in:
Bibliographic Details
Main Authors: Bamaga, S. O., Tahir, M. M., Tan, C. S.
Format: Article
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/47432/
http://scholarsmine.mst.edu/cgi/viewcontent.cgi?article=1840&context=isccss
Tags: Add Tag
No Tags, Be the first to tag this record!