Experimental evaluation of flush end-plate connection with built-up hybrid beam section

Flush end-plate connections in steel construction have received much attention recently from researchers and structural engineers due to their simplicity in fabrication and high connection ductility. Typical flush end-plate connection with reduced beam-to-end plate welding integrated with built-up h...

Full description

Saved in:
Bibliographic Details
Main Authors: Shek, Poi Ngian, Md. Tahir, Mahmood, Sulaiman, Arizu, Tan, Cher Siang
Format: Article
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/46957/
http://dx.doi.org/10.1260/1369-4332.15.2.331
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.46957
record_format eprints
spelling my.utm.469572017-09-27T04:39:08Z http://eprints.utm.my/id/eprint/46957/ Experimental evaluation of flush end-plate connection with built-up hybrid beam section Shek, Poi Ngian Md. Tahir, Mahmood Sulaiman, Arizu Tan, Cher Siang TA Engineering (General). Civil engineering (General) Flush end-plate connections in steel construction have received much attention recently from researchers and structural engineers due to their simplicity in fabrication and high connection ductility. Typical flush end-plate connection with reduced beam-to-end plate welding integrated with built-up hybrid beam section is tested in this study with the aims to reduce the cost of fabrication and materials. Four tests were conducted to investigate the behaviour of the proposed flush end-plate connections subjected to moment. Four full-scale beam-to-column joints were tested with the objective to evaluate failure modes, moment resistance, initial rotational stiffness and rotational capacity of the connections. The experimental results are compared with the existing theoretical model with several modifications. The proposed theoretical model had well predicted the connections' moment resistance with reasonable rotation capacity. All tested connections were classified as partial strength in accordance to EC 3: Part 1.8 and well validated with the experimental results. 2012 Article PeerReviewed Shek, Poi Ngian and Md. Tahir, Mahmood and Sulaiman, Arizu and Tan, Cher Siang (2012) Experimental evaluation of flush end-plate connection with built-up hybrid beam section. Advances In Structural Engineering, 15 (2). pp. 331-341. ISSN 1369-4332 http://dx.doi.org/10.1260/1369-4332.15.2.331
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Shek, Poi Ngian
Md. Tahir, Mahmood
Sulaiman, Arizu
Tan, Cher Siang
Experimental evaluation of flush end-plate connection with built-up hybrid beam section
description Flush end-plate connections in steel construction have received much attention recently from researchers and structural engineers due to their simplicity in fabrication and high connection ductility. Typical flush end-plate connection with reduced beam-to-end plate welding integrated with built-up hybrid beam section is tested in this study with the aims to reduce the cost of fabrication and materials. Four tests were conducted to investigate the behaviour of the proposed flush end-plate connections subjected to moment. Four full-scale beam-to-column joints were tested with the objective to evaluate failure modes, moment resistance, initial rotational stiffness and rotational capacity of the connections. The experimental results are compared with the existing theoretical model with several modifications. The proposed theoretical model had well predicted the connections' moment resistance with reasonable rotation capacity. All tested connections were classified as partial strength in accordance to EC 3: Part 1.8 and well validated with the experimental results.
format Article
author Shek, Poi Ngian
Md. Tahir, Mahmood
Sulaiman, Arizu
Tan, Cher Siang
author_facet Shek, Poi Ngian
Md. Tahir, Mahmood
Sulaiman, Arizu
Tan, Cher Siang
author_sort Shek, Poi Ngian
title Experimental evaluation of flush end-plate connection with built-up hybrid beam section
title_short Experimental evaluation of flush end-plate connection with built-up hybrid beam section
title_full Experimental evaluation of flush end-plate connection with built-up hybrid beam section
title_fullStr Experimental evaluation of flush end-plate connection with built-up hybrid beam section
title_full_unstemmed Experimental evaluation of flush end-plate connection with built-up hybrid beam section
title_sort experimental evaluation of flush end-plate connection with built-up hybrid beam section
publishDate 2012
url http://eprints.utm.my/id/eprint/46957/
http://dx.doi.org/10.1260/1369-4332.15.2.331
_version_ 1643652191904333824
score 13.214268