Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments

Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D...

Full description

Saved in:
Bibliographic Details
Main Authors: Wee, Lai Khin, Chai, Hum Y., Samsury, Sharul R., Mujamil, Naizaithull F., Supriyanto, Eko
Format: Article
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/46706/1/Wee.L.K_2012_Comparative%20studies%20of%20two%20dimensional%20and%20three%20dimensional%20ultrasonic%20nuchal.pdf
http://eprints.utm.my/id/eprint/46706/
http://dx.doi.org/10.1590/S0001-37652012000400030
http://dx.doi.org/10.1590/S0001-37652012000400030
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.46706
record_format eprints
spelling my.utm.467062017-09-18T04:32:31Z http://eprints.utm.my/id/eprint/46706/ Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments Wee, Lai Khin Chai, Hum Y. Samsury, Sharul R. Mujamil, Naizaithull F. Supriyanto, Eko RJ Pediatrics Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information. 2012 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/46706/1/Wee.L.K_2012_Comparative%20studies%20of%20two%20dimensional%20and%20three%20dimensional%20ultrasonic%20nuchal.pdf Wee, Lai Khin and Chai, Hum Y. and Samsury, Sharul R. and Mujamil, Naizaithull F. and Supriyanto, Eko (2012) Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments. Anais da Academia Brasileira de Ciencias, 84 (4). pp. 1157-1168. ISSN 0001-3765 http://dx.doi.org/10.1590/S0001-37652012000400030 http://dx.doi.org/10.1590/S0001-37652012000400030
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic RJ Pediatrics
spellingShingle RJ Pediatrics
Wee, Lai Khin
Chai, Hum Y.
Samsury, Sharul R.
Mujamil, Naizaithull F.
Supriyanto, Eko
Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
description Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.
format Article
author Wee, Lai Khin
Chai, Hum Y.
Samsury, Sharul R.
Mujamil, Naizaithull F.
Supriyanto, Eko
author_facet Wee, Lai Khin
Chai, Hum Y.
Samsury, Sharul R.
Mujamil, Naizaithull F.
Supriyanto, Eko
author_sort Wee, Lai Khin
title Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
title_short Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
title_full Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
title_fullStr Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
title_full_unstemmed Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
title_sort comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
publishDate 2012
url http://eprints.utm.my/id/eprint/46706/1/Wee.L.K_2012_Comparative%20studies%20of%20two%20dimensional%20and%20three%20dimensional%20ultrasonic%20nuchal.pdf
http://eprints.utm.my/id/eprint/46706/
http://dx.doi.org/10.1590/S0001-37652012000400030
http://dx.doi.org/10.1590/S0001-37652012000400030
_version_ 1643652115153813504
score 13.160551