A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed
Combustion behaviour of municipal solid waste in a fluidised bed was studied. The effect of fluidisation number and total air factor on the combustion behaviour of municipal solid waste of high moisture content in a fluidised bed combustor was investigated. The first part of the combustion study was...
محفوظ في:
المؤلفون الرئيسيون: | , , , , |
---|---|
التنسيق: | مقال |
منشور في: |
2012
|
الموضوعات: | |
الوصول للمادة أونلاين: | http://eprints.utm.my/id/eprint/46531/ https://dx.doi.org/10.1016/j.applthermaleng.2011.10.056 |
الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
id |
my.utm.46531 |
---|---|
record_format |
eprints |
spelling |
my.utm.465312017-09-12T07:48:16Z http://eprints.utm.my/id/eprint/46531/ A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed Johari, Anwar Hashim, Haslenda Taib, Rozainee Mat, Ramli Jusoh, Mazura QD Chemistry Combustion behaviour of municipal solid waste in a fluidised bed was studied. The effect of fluidisation number and total air factor on the combustion behaviour of municipal solid waste of high moisture content in a fluidised bed combustor was investigated. The first part of the combustion study was carried out at fluidisation numbers ranging from 5 to 7 Umf with a fixed Primary Air Factor (AF) of 0.8. Results show that the optimum fluidisation number is 5 Umf in which the bed temperature sustained longer. The second part of the study dealt with the effect of secondary air on the bed combustion behaviour conducted at 5 Umf. The chosen range of secondary air factor is 0–0.6. It is revealed that the addition of secondary air has no effect on the bed combustion. 2012 Article PeerReviewed Johari, Anwar and Hashim, Haslenda and Taib, Rozainee and Mat, Ramli and Jusoh, Mazura (2012) A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed. Applied Thermal Engineering, 36 . pp. 403-405. ISSN 1359-4311 https://dx.doi.org/10.1016/j.applthermaleng.2011.10.056 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
QD Chemistry |
spellingShingle |
QD Chemistry Johari, Anwar Hashim, Haslenda Taib, Rozainee Mat, Ramli Jusoh, Mazura A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed |
description |
Combustion behaviour of municipal solid waste in a fluidised bed was studied. The effect of fluidisation number and total air factor on the combustion behaviour of municipal solid waste of high moisture content in a fluidised bed combustor was investigated. The first part of the combustion study was carried out at fluidisation numbers ranging from 5 to 7 Umf with a fixed Primary Air Factor (AF) of 0.8. Results show that the optimum fluidisation number is 5 Umf in which the bed temperature sustained longer. The second part of the study dealt with the effect of secondary air on the bed combustion behaviour conducted at 5 Umf. The chosen range of secondary air factor is 0–0.6. It is revealed that the addition of secondary air has no effect on the bed combustion. |
format |
Article |
author |
Johari, Anwar Hashim, Haslenda Taib, Rozainee Mat, Ramli Jusoh, Mazura |
author_facet |
Johari, Anwar Hashim, Haslenda Taib, Rozainee Mat, Ramli Jusoh, Mazura |
author_sort |
Johari, Anwar |
title |
A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed |
title_short |
A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed |
title_full |
A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed |
title_fullStr |
A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed |
title_full_unstemmed |
A short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed |
title_sort |
short note: effects of fludisation number and total air factor on the combustion of municipal solid waste of high moisture content in a fluidised bed |
publishDate |
2012 |
url |
http://eprints.utm.my/id/eprint/46531/ https://dx.doi.org/10.1016/j.applthermaleng.2011.10.056 |
_version_ |
1643652062847696896 |
score |
13.251813 |