Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples

Despite the abundance of natural gas reserves in Malaysia coupled with serious government thrusts to promote cogeneration, its (cogeneration) development pace lags far off expectations. There are widespread fallacies among potential cogeneration developers and concerned professionals that cogenerati...

Full description

Saved in:
Bibliographic Details
Main Authors: Shaaban, Mohamed, Azit, Abu Hanifah, Mohamed Nor, Khalid
Format: Article
Published: Elsevier Ltd 2011
Subjects:
Online Access:http://eprints.utm.my/id/eprint/44952/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.44952
record_format eprints
spelling my.utm.449522017-09-18T07:46:55Z http://eprints.utm.my/id/eprint/44952/ Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples Shaaban, Mohamed Azit, Abu Hanifah Mohamed Nor, Khalid GA Mathematical geography. Cartography Despite the abundance of natural gas reserves in Malaysia coupled with serious government thrusts to promote cogeneration, its (cogeneration) development pace lags far off expectations. There are widespread fallacies among potential cogeneration developers and concerned professionals that cogeneration is uncompetitive in Malaysia due to existing policies of subsidized gas prices and grid-connection charges. This paper exposes these fallacies through counterexamples of practical cogeneration system design and evaluation of some segments of the industrial and service sectors in Peninsular Malaysia. The electrical and thermal characteristics of the cogeneration were modeled based on heat rate characteristics at partial loading patterns. A hierarchical mathematical programming approach that uses mixed-integer nonlinear optimization and dynamic programming principle, if necessary, is employed to determine the optimal size of cogeneration and its related auxiliary equipment as well as the optimal operation schedule. Financial assessment is integrated at a later stage to assess the economic viability of the system. Analyses of the cogeneration potential for several facilities of miscellaneous activities were carried out using various gas and electricity prices. Results obtained consistently rebuff the perpetuated fallacies and confirm that there is no real barrier to cogeneration development in Malaysia under current policies of gas prices and electricity tariffs. Elsevier Ltd 2011 Article PeerReviewed Shaaban, Mohamed and Azit, Abu Hanifah and Mohamed Nor, Khalid (2011) Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples. Energy Policy, 39 (9). pp. 5063-5075. ISSN 0301-4215
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic GA Mathematical geography. Cartography
spellingShingle GA Mathematical geography. Cartography
Shaaban, Mohamed
Azit, Abu Hanifah
Mohamed Nor, Khalid
Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples
description Despite the abundance of natural gas reserves in Malaysia coupled with serious government thrusts to promote cogeneration, its (cogeneration) development pace lags far off expectations. There are widespread fallacies among potential cogeneration developers and concerned professionals that cogeneration is uncompetitive in Malaysia due to existing policies of subsidized gas prices and grid-connection charges. This paper exposes these fallacies through counterexamples of practical cogeneration system design and evaluation of some segments of the industrial and service sectors in Peninsular Malaysia. The electrical and thermal characteristics of the cogeneration were modeled based on heat rate characteristics at partial loading patterns. A hierarchical mathematical programming approach that uses mixed-integer nonlinear optimization and dynamic programming principle, if necessary, is employed to determine the optimal size of cogeneration and its related auxiliary equipment as well as the optimal operation schedule. Financial assessment is integrated at a later stage to assess the economic viability of the system. Analyses of the cogeneration potential for several facilities of miscellaneous activities were carried out using various gas and electricity prices. Results obtained consistently rebuff the perpetuated fallacies and confirm that there is no real barrier to cogeneration development in Malaysia under current policies of gas prices and electricity tariffs.
format Article
author Shaaban, Mohamed
Azit, Abu Hanifah
Mohamed Nor, Khalid
author_facet Shaaban, Mohamed
Azit, Abu Hanifah
Mohamed Nor, Khalid
author_sort Shaaban, Mohamed
title Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples
title_short Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples
title_full Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples
title_fullStr Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples
title_full_unstemmed Grid integration policies of gas-fired cogeneration in Peninsular Malaysia: fallacies and counterexamples
title_sort grid integration policies of gas-fired cogeneration in peninsular malaysia: fallacies and counterexamples
publisher Elsevier Ltd
publishDate 2011
url http://eprints.utm.my/id/eprint/44952/
_version_ 1643651596997885952
score 13.214268