Investigating the performance of grouted sleeve connectors under tensile load
A sleeve combined with grout is a cylindrical connector used to join two discontinuous steel reinforcement bars without complying to the conventional lap length. It acts as the connection for joining steel reinforcement bars to safely transfer the tensile force from one reinforcement bar to the othe...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Construction Research Institute of Malaysia
2010
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/43981/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.43981 |
---|---|
record_format |
eprints |
spelling |
my.utm.439812017-02-15T06:56:07Z http://eprints.utm.my/id/eprint/43981/ Investigating the performance of grouted sleeve connectors under tensile load Abd. Rahman, Ahmad Baharuddin Ling, Jen Hua Ibrahim, Izni Syahrizal Abd. Hamid, Zuhairi TA Engineering (General). Civil engineering (General) A sleeve combined with grout is a cylindrical connector used to join two discontinuous steel reinforcement bars without complying to the conventional lap length. It acts as the connection for joining steel reinforcement bars to safely transfer the tensile force from one reinforcement bar to the other to ensure the integrity of a structural frame system. The objective of this research was to investigate the behavior and the feasibility of fifteen new proposed grouted sleeve connectors for the connection of precast concrete components. The connectors were tested to failure under incremental tensile load. The configurations of the grouted sleeve connectors were varied and their tensile performances were evaluated in terms of the ultimate tensile resistance, stiffness, yield strength, ductility and failure modes. The results show that the grouted splice sleeve connectors could provide comparable ultimate tensile strength of the connected steel bars. It is seen that the bond between bar-and-grout,and also between grout-and-sleeve are essential to the success of the tensile load transfer between the steel bars. It is also seen that the confinement provided by the sleeve enhances the bar-and-grout bond dramatically by controlling the splitting cracks. Construction Research Institute of Malaysia 2010 Article PeerReviewed Abd. Rahman, Ahmad Baharuddin and Ling, Jen Hua and Ibrahim, Izni Syahrizal and Abd. Hamid, Zuhairi (2010) Investigating the performance of grouted sleeve connectors under tensile load. Malaysian Construction Research Journal, 6 . pp. 39-55. ISSN 1985-3807 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Abd. Rahman, Ahmad Baharuddin Ling, Jen Hua Ibrahim, Izni Syahrizal Abd. Hamid, Zuhairi Investigating the performance of grouted sleeve connectors under tensile load |
description |
A sleeve combined with grout is a cylindrical connector used to join two discontinuous steel reinforcement bars without complying to the conventional lap length. It acts as the connection for joining steel reinforcement bars to safely transfer the tensile force from one reinforcement bar to the other to ensure the integrity of a structural frame system. The objective of this research was to investigate the behavior and the feasibility of fifteen new proposed grouted sleeve connectors for the connection of precast concrete components. The connectors were tested to failure under incremental tensile load. The configurations of the grouted sleeve connectors were varied and their tensile performances were evaluated in terms of the ultimate tensile resistance, stiffness, yield strength, ductility and failure modes. The results show that the grouted splice sleeve connectors could provide comparable ultimate tensile strength of the connected steel bars. It is seen that the bond between bar-and-grout,and also between grout-and-sleeve are essential to the success of the tensile load transfer between the steel bars. It is also seen that the confinement provided by the sleeve enhances the bar-and-grout bond dramatically by controlling the splitting cracks. |
format |
Article |
author |
Abd. Rahman, Ahmad Baharuddin Ling, Jen Hua Ibrahim, Izni Syahrizal Abd. Hamid, Zuhairi |
author_facet |
Abd. Rahman, Ahmad Baharuddin Ling, Jen Hua Ibrahim, Izni Syahrizal Abd. Hamid, Zuhairi |
author_sort |
Abd. Rahman, Ahmad Baharuddin |
title |
Investigating the performance of grouted sleeve connectors under tensile load
|
title_short |
Investigating the performance of grouted sleeve connectors under tensile load
|
title_full |
Investigating the performance of grouted sleeve connectors under tensile load
|
title_fullStr |
Investigating the performance of grouted sleeve connectors under tensile load
|
title_full_unstemmed |
Investigating the performance of grouted sleeve connectors under tensile load
|
title_sort |
investigating the performance of grouted sleeve connectors under tensile load |
publisher |
Construction Research Institute of Malaysia |
publishDate |
2010 |
url |
http://eprints.utm.my/id/eprint/43981/ |
_version_ |
1643651334761611264 |
score |
13.209306 |