Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery

This thesis is concerned with the development of mathematical models for the computation and simulation of biomagnetic fluid flow in either a stenosed or aneurysmal artery in the presence of non-uniform magnetic fields. The mathematical models take into account blood rheology where blood behaves as...

Full description

Saved in:
Bibliographic Details
Main Author: Rusli, Nursalasawati
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/43963/5/NursalasawatiRusliPFS2013.pdf
http://eprints.utm.my/id/eprint/43963/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.43963
record_format eprints
spelling my.utm.439632017-07-23T06:07:24Z http://eprints.utm.my/id/eprint/43963/ Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery Rusli, Nursalasawati Q Science (General) This thesis is concerned with the development of mathematical models for the computation and simulation of biomagnetic fluid flow in either a stenosed or aneurysmal artery in the presence of non-uniform magnetic fields. The mathematical models take into account blood rheology where blood behaves as a magnetic fluid due to the complex interaction of intercellular protein, cell membrane and haemoglobin. The present study involves steady three-dimensional biomagnetic fluid flow and mass transfer through a horizontal cylinder. Numerical solutions obtained through a finite volume method shows that the magnetisation force has an effect on the fluid concentration and exerts a greater influence on the secondary flow motions compared to that caused by the Lorentz force. Earlier studies allow only Lorentz force due to uniform magnetic fields but neglect the effect of magnetisation force. Here, a modified finite difference method has also been designed specifically to study separately the effect of magnetisation force, Lorentz force or both, on a steady two-dimensional channel flow. It is observed that a distorted asymmetric flow profile is presented near the magnetic source and that the Lorentz force gives little influence to the flow behaviours, vindicating previous proposition that the Lorentz force need not be considered in the model of biomagnetic fluid flow. 2013-03 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/43963/5/NursalasawatiRusliPFS2013.pdf Rusli, Nursalasawati (2013) Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery. PhD thesis, Universiti Teknologi Malaysia, Faculty of Science.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic Q Science (General)
spellingShingle Q Science (General)
Rusli, Nursalasawati
Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery
description This thesis is concerned with the development of mathematical models for the computation and simulation of biomagnetic fluid flow in either a stenosed or aneurysmal artery in the presence of non-uniform magnetic fields. The mathematical models take into account blood rheology where blood behaves as a magnetic fluid due to the complex interaction of intercellular protein, cell membrane and haemoglobin. The present study involves steady three-dimensional biomagnetic fluid flow and mass transfer through a horizontal cylinder. Numerical solutions obtained through a finite volume method shows that the magnetisation force has an effect on the fluid concentration and exerts a greater influence on the secondary flow motions compared to that caused by the Lorentz force. Earlier studies allow only Lorentz force due to uniform magnetic fields but neglect the effect of magnetisation force. Here, a modified finite difference method has also been designed specifically to study separately the effect of magnetisation force, Lorentz force or both, on a steady two-dimensional channel flow. It is observed that a distorted asymmetric flow profile is presented near the magnetic source and that the Lorentz force gives little influence to the flow behaviours, vindicating previous proposition that the Lorentz force need not be considered in the model of biomagnetic fluid flow.
format Thesis
author Rusli, Nursalasawati
author_facet Rusli, Nursalasawati
author_sort Rusli, Nursalasawati
title Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery
title_short Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery
title_full Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery
title_fullStr Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery
title_full_unstemmed Computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery
title_sort computational modelling and simulation of biomagnetic fluid flow in a stenotic and aneurysmal artery
publishDate 2013
url http://eprints.utm.my/id/eprint/43963/5/NursalasawatiRusliPFS2013.pdf
http://eprints.utm.my/id/eprint/43963/
_version_ 1643651329396047872
score 13.251813