Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction

The integration of distributed generation (DG) into the distribution system brings conspicuous technical and economic benefits to the grid. Yet installation of non optimized sizes of DGs at arbitrary locations can result in degraded voltage profile and increased system losses. This would consequentl...

Full description

Saved in:
Bibliographic Details
Main Authors: Abd. El-Moneim Shaaban, Mohamed, Petinrin, J. O.
Format: Article
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/40825/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.40825
record_format eprints
spelling my.utm.408252017-08-14T01:42:59Z http://eprints.utm.my/id/eprint/40825/ Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction Abd. El-Moneim Shaaban, Mohamed Petinrin, J. O. TK Electrical engineering. Electronics Nuclear engineering The integration of distributed generation (DG) into the distribution system brings conspicuous technical and economic benefits to the grid. Yet installation of non optimized sizes of DGs at arbitrary locations can result in degraded voltage profile and increased system losses. This would consequently drive cost escalation, creating an effect against the desired. It is therefore expedient that the sizing and location of DG units should be prudently planned and determined. This paper presents an analytical technique to determine the optimal size and siting of DGs in a distribution system for active power loss reduction and voltage profile improvement. DG unit sizing and siting are calculated using a sensitivity index that combines the exact loss formula and voltage sensitivity coefficients. Investigation is carried out on the IEEE 13 bus test feeder to validate the effectiveness of the proposed method. Aspects related to the connection of non-dispatchable renewable DG to the distribution network and the use of energy storage, as a representative of smart grid technologies, is also discussed. 2013 Article PeerReviewed Abd. El-Moneim Shaaban, Mohamed and Petinrin, J. O. (2013) Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction. International Journal of Smart Grid and Clean Energy, 2 (3). pp. 350-356. ISSN 2315-4462
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abd. El-Moneim Shaaban, Mohamed
Petinrin, J. O.
Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction
description The integration of distributed generation (DG) into the distribution system brings conspicuous technical and economic benefits to the grid. Yet installation of non optimized sizes of DGs at arbitrary locations can result in degraded voltage profile and increased system losses. This would consequently drive cost escalation, creating an effect against the desired. It is therefore expedient that the sizing and location of DG units should be prudently planned and determined. This paper presents an analytical technique to determine the optimal size and siting of DGs in a distribution system for active power loss reduction and voltage profile improvement. DG unit sizing and siting are calculated using a sensitivity index that combines the exact loss formula and voltage sensitivity coefficients. Investigation is carried out on the IEEE 13 bus test feeder to validate the effectiveness of the proposed method. Aspects related to the connection of non-dispatchable renewable DG to the distribution network and the use of energy storage, as a representative of smart grid technologies, is also discussed.
format Article
author Abd. El-Moneim Shaaban, Mohamed
Petinrin, J. O.
author_facet Abd. El-Moneim Shaaban, Mohamed
Petinrin, J. O.
author_sort Abd. El-Moneim Shaaban, Mohamed
title Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction
title_short Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction
title_full Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction
title_fullStr Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction
title_full_unstemmed Sizing and Siting of Distributed Generation in Distribution Systems for Voltage Improvement and Loss Reduction
title_sort sizing and siting of distributed generation in distribution systems for voltage improvement and loss reduction
publishDate 2013
url http://eprints.utm.my/id/eprint/40825/
_version_ 1643650567497580544
score 13.211869