Cement properties effects to steel corrosion rate
Series of experiments were conducted in analyzing the effect of fluid loss rate of cement slurry due to the existence of permeability contributing to the corrosion rate of cement slurry. Both class G and ordinary Portland cement (OPC) with different fluid loss were used to compare the cement protect...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Chemical & Natural Resources Engineering, UTM Skudai
1997
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/4045/1/SKMBT_60007071915290.pdf http://eprints.utm.my/id/eprint/4045/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.4045 |
---|---|
record_format |
eprints |
spelling |
my.utm.40452017-10-19T06:29:16Z http://eprints.utm.my/id/eprint/4045/ Cement properties effects to steel corrosion rate Samsuri, Ariffin K. S., Surej Chandra, M. H. M. A., Yeoh B., Suresh T Technology (General) Series of experiments were conducted in analyzing the effect of fluid loss rate of cement slurry due to the existence of permeability contributing to the corrosion rate of cement slurry. Both class G and ordinary Portland cement (OPC) with different fluid loss were used to compare the cement protective effect on corrosion. The fluid loss was measured according to the API spec 10.3.5% Natrium Chloride (NaCl) solution was used as the carrion environment for reservoir and atmospheric conditions. A laboratory experiments is was done to study the influence of permeability for both types of cement. Permeability value was changed by alternating water cement ratio. Steel was put into cement mixture and left submerged in a brine solution. Submersion was done in atmospheric condition with a fixed temperature of 32 0C and 52)C for reservoir condition. For both experiments, the A.C. Impendence technique was used. Results were discussed in depth to state that cement slurry with higher fluid loss will give a lower corrosion resistance, Rp and thus increasing the corrosion rate. Corrosion rate is higher at reservoir condition and both class G and OPC show the same characteristic and behavior. However, class G cement shows better corrosion effective characteristic. Results from the permeability experiment shows that the permeability of OPC system is higher than the class G cement as well as the permeability being higher in reservoir condition rather than atmospheric condition. Faculty of Chemical & Natural Resources Engineering, UTM Skudai 1997-10-13 Article NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/4045/1/SKMBT_60007071915290.pdf Samsuri, Ariffin and K. S., Surej and Chandra, M. H. and M. A., Yeoh and B., Suresh (1997) Cement properties effects to steel corrosion rate. Proceedings of Regional Symposium on Chemical Engineering '97, 2 . pp. 575-580. |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Samsuri, Ariffin K. S., Surej Chandra, M. H. M. A., Yeoh B., Suresh Cement properties effects to steel corrosion rate |
description |
Series of experiments were conducted in analyzing the effect of fluid loss rate of cement slurry due to the existence of permeability contributing to the corrosion rate of cement slurry. Both class G and ordinary Portland cement (OPC) with different fluid loss were used to compare the cement protective effect on corrosion. The fluid loss was measured according to the API spec 10.3.5% Natrium Chloride (NaCl) solution was used as the carrion environment for reservoir and atmospheric conditions. A laboratory experiments is was done to study the influence of permeability for both types of cement. Permeability value was changed by alternating water cement ratio. Steel was put into cement mixture and left submerged in a brine solution. Submersion was done in atmospheric condition with a fixed temperature of 32 0C and 52)C for reservoir condition. For both experiments, the A.C. Impendence technique was used. Results were discussed in depth to state that cement slurry with higher fluid loss will give a lower corrosion resistance, Rp and thus increasing the corrosion rate. Corrosion rate is higher at reservoir condition and both class G and OPC show the same characteristic and behavior. However, class G cement shows better corrosion effective characteristic. Results from the permeability experiment shows that the permeability of OPC system is higher than the class G cement as well as the permeability being higher in reservoir condition rather than atmospheric condition.
|
format |
Article |
author |
Samsuri, Ariffin K. S., Surej Chandra, M. H. M. A., Yeoh B., Suresh |
author_facet |
Samsuri, Ariffin K. S., Surej Chandra, M. H. M. A., Yeoh B., Suresh |
author_sort |
Samsuri, Ariffin |
title |
Cement properties effects to steel corrosion rate |
title_short |
Cement properties effects to steel corrosion rate |
title_full |
Cement properties effects to steel corrosion rate |
title_fullStr |
Cement properties effects to steel corrosion rate |
title_full_unstemmed |
Cement properties effects to steel corrosion rate |
title_sort |
cement properties effects to steel corrosion rate |
publisher |
Faculty of Chemical & Natural Resources Engineering, UTM Skudai |
publishDate |
1997 |
url |
http://eprints.utm.my/id/eprint/4045/1/SKMBT_60007071915290.pdf http://eprints.utm.my/id/eprint/4045/ |
_version_ |
1643643951937224704 |
score |
13.18916 |