Ground fault currents in unit generator transformer at various voltage and transformer configurations

Single line to ground fault (SLGF) is the most frequent fault probable to occur in an electric power system. The effect of ground fault is determined by voltage transformer and transformer configurations. In this paper, the simulation showed the performance generator within the SLGF at various trans...

Full description

Saved in:
Bibliographic Details
Main Authors: Sultan, Ahmad Rizal, Mustafa, Mohd. Wazir
Format: Article
Language:English
Published: IEEE 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/40390/1/AhmadRizalSultan2013_GroundFaultCurrentsinUnitGenerator.pdf
http://eprints.utm.my/id/eprint/40390/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.40390
record_format eprints
spelling my.utm.403902019-03-25T08:19:36Z http://eprints.utm.my/id/eprint/40390/ Ground fault currents in unit generator transformer at various voltage and transformer configurations Sultan, Ahmad Rizal Mustafa, Mohd. Wazir TK Electrical engineering. Electronics Nuclear engineering Single line to ground fault (SLGF) is the most frequent fault probable to occur in an electric power system. The effect of ground fault is determined by voltage transformer and transformer configurations. In this paper, the simulation showed the performance generator within the SLGF at various transformer configurations. Simulation was conducted in DIgSILENT PowerFactory 14.0. and the results were analyzed, presenting comparison of the fault impact at various transformer connections. The model of transformer connection for each side (primary and secondary) used were Y, Yn, Z, Zn and ? . The Y, Z and ? secondary side of transformer configuration were utilized to block the single line to ground fault at the generator bus. It was clearly shown that the SLGF at the generator bus was highly dependent upon the type of the transformer configurations used during the ground fault at the secondary side of transformer. IEEE 2013 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/40390/1/AhmadRizalSultan2013_GroundFaultCurrentsinUnitGenerator.pdf Sultan, Ahmad Rizal and Mustafa, Mohd. Wazir (2013) Ground fault currents in unit generator transformer at various voltage and transformer configurations. Indian Journal of Applied Research, 3 (5). pp. 224-227. ISSN 2249-555X
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Sultan, Ahmad Rizal
Mustafa, Mohd. Wazir
Ground fault currents in unit generator transformer at various voltage and transformer configurations
description Single line to ground fault (SLGF) is the most frequent fault probable to occur in an electric power system. The effect of ground fault is determined by voltage transformer and transformer configurations. In this paper, the simulation showed the performance generator within the SLGF at various transformer configurations. Simulation was conducted in DIgSILENT PowerFactory 14.0. and the results were analyzed, presenting comparison of the fault impact at various transformer connections. The model of transformer connection for each side (primary and secondary) used were Y, Yn, Z, Zn and ? . The Y, Z and ? secondary side of transformer configuration were utilized to block the single line to ground fault at the generator bus. It was clearly shown that the SLGF at the generator bus was highly dependent upon the type of the transformer configurations used during the ground fault at the secondary side of transformer.
format Article
author Sultan, Ahmad Rizal
Mustafa, Mohd. Wazir
author_facet Sultan, Ahmad Rizal
Mustafa, Mohd. Wazir
author_sort Sultan, Ahmad Rizal
title Ground fault currents in unit generator transformer at various voltage and transformer configurations
title_short Ground fault currents in unit generator transformer at various voltage and transformer configurations
title_full Ground fault currents in unit generator transformer at various voltage and transformer configurations
title_fullStr Ground fault currents in unit generator transformer at various voltage and transformer configurations
title_full_unstemmed Ground fault currents in unit generator transformer at various voltage and transformer configurations
title_sort ground fault currents in unit generator transformer at various voltage and transformer configurations
publisher IEEE
publishDate 2013
url http://eprints.utm.my/id/eprint/40390/1/AhmadRizalSultan2013_GroundFaultCurrentsinUnitGenerator.pdf
http://eprints.utm.my/id/eprint/40390/
_version_ 1643650462542462976
score 13.160551