energy analysis of an air conditioning system using fuzzy logic control

Reducing energy consumption and to ensure thermal comfort are two important considerations for the designing an air conditioning system. An alternative approach to reduce energy consumption proposed in this study is to use a variable speed compressor. The control strategy will be proposed using the...

Full description

Saved in:
Bibliographic Details
Main Authors: Nasution, Henry, Jamaluddin, Hishamuddin, Mohd. Syeriff, Jamaluddin
Format: Article
Language:English
Published: Universitas Ahmad Dahlan (UAD) 2011
Subjects:
Online Access:http://eprints.utm.my/id/eprint/39869/1/HishamuddinJamaluddin2011_EnergyAnalysisforAirConditioningSystem.pdf
http://eprints.utm.my/id/eprint/39869/
http://journal.uad.ac.id/index.php?journal=TELKOMNIKA&page=article&op=view&path%5B%5D=680
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.39869
record_format eprints
spelling my.utm.398692019-03-05T01:34:19Z http://eprints.utm.my/id/eprint/39869/ energy analysis of an air conditioning system using fuzzy logic control Nasution, Henry Jamaluddin, Hishamuddin Mohd. Syeriff, Jamaluddin TJ Mechanical engineering and machinery Reducing energy consumption and to ensure thermal comfort are two important considerations for the designing an air conditioning system. An alternative approach to reduce energy consumption proposed in this study is to use a variable speed compressor. The control strategy will be proposed using the fuzzy logic controller (FLC). FLC was developed to imitate the performance of human expert operators by encoding their knowledge in the form of linguistic rules. The system is installed on a thermal environmental room with a data acquisition system to monitor the temperature of the room, coefficient of performance (COP), energy consumption and energy saving. The measurements taken during the two hour experimental periods at 5-minutes interval times for temperature setpoints of 20oC, 22oC and 24oC with internal heat loads 0, 500, 700 and 1000 W. The experimental results indicate that the proposed technique can save energy in comparison with On/Off and proportional-integral-derivative (PID) control. Universitas Ahmad Dahlan (UAD) 2011 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/39869/1/HishamuddinJamaluddin2011_EnergyAnalysisforAirConditioningSystem.pdf Nasution, Henry and Jamaluddin, Hishamuddin and Mohd. Syeriff, Jamaluddin (2011) energy analysis of an air conditioning system using fuzzy logic control. Jurnal TELKOMNIKA, 9 (1). pp. 139-150. ISSN 1693-6930 http://journal.uad.ac.id/index.php?journal=TELKOMNIKA&page=article&op=view&path%5B%5D=680
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Nasution, Henry
Jamaluddin, Hishamuddin
Mohd. Syeriff, Jamaluddin
energy analysis of an air conditioning system using fuzzy logic control
description Reducing energy consumption and to ensure thermal comfort are two important considerations for the designing an air conditioning system. An alternative approach to reduce energy consumption proposed in this study is to use a variable speed compressor. The control strategy will be proposed using the fuzzy logic controller (FLC). FLC was developed to imitate the performance of human expert operators by encoding their knowledge in the form of linguistic rules. The system is installed on a thermal environmental room with a data acquisition system to monitor the temperature of the room, coefficient of performance (COP), energy consumption and energy saving. The measurements taken during the two hour experimental periods at 5-minutes interval times for temperature setpoints of 20oC, 22oC and 24oC with internal heat loads 0, 500, 700 and 1000 W. The experimental results indicate that the proposed technique can save energy in comparison with On/Off and proportional-integral-derivative (PID) control.
format Article
author Nasution, Henry
Jamaluddin, Hishamuddin
Mohd. Syeriff, Jamaluddin
author_facet Nasution, Henry
Jamaluddin, Hishamuddin
Mohd. Syeriff, Jamaluddin
author_sort Nasution, Henry
title energy analysis of an air conditioning system using fuzzy logic control
title_short energy analysis of an air conditioning system using fuzzy logic control
title_full energy analysis of an air conditioning system using fuzzy logic control
title_fullStr energy analysis of an air conditioning system using fuzzy logic control
title_full_unstemmed energy analysis of an air conditioning system using fuzzy logic control
title_sort energy analysis of an air conditioning system using fuzzy logic control
publisher Universitas Ahmad Dahlan (UAD)
publishDate 2011
url http://eprints.utm.my/id/eprint/39869/1/HishamuddinJamaluddin2011_EnergyAnalysisforAirConditioningSystem.pdf
http://eprints.utm.my/id/eprint/39869/
http://journal.uad.ac.id/index.php?journal=TELKOMNIKA&page=article&op=view&path%5B%5D=680