Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography
In this paper, ultrasonic transmission mode tomography was used to visualize the two phase liquid/gas flow in a pipe/vessel. The sensing element consists of 8, 16 and 32 units ultrasonic transceivers were used to cover the pipe cross-section at different time. The motivation of this paper is to anal...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
International Frequency Sensor Association (IFSA)
2010
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/38416/2/PAPER_IFSA_PUBLISHED%28Jurnal%20En%20Zulkarnay%29.pdf http://eprints.utm.my/id/eprint/38416/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.38416 |
---|---|
record_format |
eprints |
spelling |
my.utm.384162017-02-15T01:47:59Z http://eprints.utm.my/id/eprint/38416/ Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography Zakaria, Zulkarnay Fazalul Rahiman, Mohd. Hafiz Abdul Rahim, Ruzairi TK Electrical engineering. Electronics Nuclear engineering In this paper, ultrasonic transmission mode tomography was used to visualize the two phase liquid/gas flow in a pipe/vessel. The sensing element consists of 8, 16 and 32 units ultrasonic transceivers were used to cover the pipe cross-section at different time. The motivation of this paper is to analyze the optimum numbers of transceivers which can give the best performance in providing better image of the two phase liquid/gas flow. This paper also details the development of the system including the ultrasonic transduction circuits, the electronic measurement circuits, the data acquisition system and the image reconstruction techniques. Ten conditions of liquid-gas flow have been simulated. The system was found capable of visualizing the internal characteristics and provides the concentration profile for the corresponding liquid and gas phases while the 32 transceivers has provided the best image for the ten conditions applied. International Frequency Sensor Association (IFSA) 2010-01 Article PeerReviewed text/html en http://eprints.utm.my/id/eprint/38416/2/PAPER_IFSA_PUBLISHED%28Jurnal%20En%20Zulkarnay%29.pdf Zakaria, Zulkarnay and Fazalul Rahiman, Mohd. Hafiz and Abdul Rahim, Ruzairi (2010) Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography. Sensors & Transducers Journal, 112 (1). pp. 24-38. ISSN 2306-8515 (Print); 1726-5479 (Electronic) |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Zakaria, Zulkarnay Fazalul Rahiman, Mohd. Hafiz Abdul Rahim, Ruzairi Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography |
description |
In this paper, ultrasonic transmission mode tomography was used to visualize the two phase liquid/gas flow in a pipe/vessel. The sensing element consists of 8, 16 and 32 units ultrasonic transceivers were used to cover the pipe cross-section at different time. The motivation of this paper is to analyze the optimum numbers of transceivers which can give the best performance in providing better image of the two phase liquid/gas flow. This paper also details the development of the system including the ultrasonic transduction circuits, the electronic measurement circuits, the data acquisition system and the image reconstruction techniques. Ten conditions of liquid-gas flow have been simulated. The system was found capable of visualizing the internal characteristics and provides the concentration profile for the corresponding liquid and gas phases while the 32 transceivers has provided the best image for the ten conditions applied. |
format |
Article |
author |
Zakaria, Zulkarnay Fazalul Rahiman, Mohd. Hafiz Abdul Rahim, Ruzairi |
author_facet |
Zakaria, Zulkarnay Fazalul Rahiman, Mohd. Hafiz Abdul Rahim, Ruzairi |
author_sort |
Zakaria, Zulkarnay |
title |
Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography
|
title_short |
Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography
|
title_full |
Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography
|
title_fullStr |
Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography
|
title_full_unstemmed |
Simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography
|
title_sort |
simulation of the two-phase liquid-gas flow through ultrasonic transceivers application in ultrasonic tomography |
publisher |
International Frequency Sensor Association (IFSA) |
publishDate |
2010 |
url |
http://eprints.utm.my/id/eprint/38416/2/PAPER_IFSA_PUBLISHED%28Jurnal%20En%20Zulkarnay%29.pdf http://eprints.utm.my/id/eprint/38416/ |
_version_ |
1643650242494595072 |
score |
13.19449 |