Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant

The concentrations of 29 elements in palm-oil mill boiler flyash emitted from a mixed fiber and shell fired-fuel palm-oil mill plant were measured using a instrumental neutron ectivation analysis (INAA). Two separate sample of flyash 1) flyash retained bt theparticulate arrestor and 2) stack-ash emi...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd. Yusoff, Mohd. Rashid, Wood, Abdul Khalik, Shaffi, Azman Firdaus
Format: Article
Language:English
Published: 1987
Subjects:
Online Access:http://eprints.utm.my/id/eprint/3785/1/SKMBT_60007061915300.pdf
http://eprints.utm.my/id/eprint/3785/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.3785
record_format eprints
spelling my.utm.37852010-06-01T03:12:11Z http://eprints.utm.my/id/eprint/3785/ Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant Mohd. Yusoff, Mohd. Rashid Wood, Abdul Khalik Shaffi, Azman Firdaus TP Chemical technology The concentrations of 29 elements in palm-oil mill boiler flyash emitted from a mixed fiber and shell fired-fuel palm-oil mill plant were measured using a instrumental neutron ectivation analysis (INAA). Two separate sample of flyash 1) flyash retained bt theparticulate arrestor and 2) stack-ash emission collected downstream of the boiler were studied. Result showed that potentially volatile elements (As, Ba, Cl, Co, Cr, Cs, Sb, Rb and Zn) were enriched in the stack-ash emission as compared to retained-ash. Gallium, K and Na were intermediately enriched and Al, Ca, Ce, Eu, Fe, La, Lu, Mn, Sc, Sm, Th, Ti, V and Yb showed equally concentrated in both samples. Study suggests that the INAA can serve as an important analytical tool in elemental pollution studies from an industrial source emission. 1987-11-17 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/3785/1/SKMBT_60007061915300.pdf Mohd. Yusoff, Mohd. Rashid and Wood, Abdul Khalik and Shaffi, Azman Firdaus (1987) Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant. A Case Study Of A Palm-Oil Mill Plant . pp. 1-10.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Mohd. Yusoff, Mohd. Rashid
Wood, Abdul Khalik
Shaffi, Azman Firdaus
Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant
description The concentrations of 29 elements in palm-oil mill boiler flyash emitted from a mixed fiber and shell fired-fuel palm-oil mill plant were measured using a instrumental neutron ectivation analysis (INAA). Two separate sample of flyash 1) flyash retained bt theparticulate arrestor and 2) stack-ash emission collected downstream of the boiler were studied. Result showed that potentially volatile elements (As, Ba, Cl, Co, Cr, Cs, Sb, Rb and Zn) were enriched in the stack-ash emission as compared to retained-ash. Gallium, K and Na were intermediately enriched and Al, Ca, Ce, Eu, Fe, La, Lu, Mn, Sc, Sm, Th, Ti, V and Yb showed equally concentrated in both samples. Study suggests that the INAA can serve as an important analytical tool in elemental pollution studies from an industrial source emission.
format Article
author Mohd. Yusoff, Mohd. Rashid
Wood, Abdul Khalik
Shaffi, Azman Firdaus
author_facet Mohd. Yusoff, Mohd. Rashid
Wood, Abdul Khalik
Shaffi, Azman Firdaus
author_sort Mohd. Yusoff, Mohd. Rashid
title Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant
title_short Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant
title_full Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant
title_fullStr Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant
title_full_unstemmed Multielemental analysis of an industrial source emission by nuetron activation analysis : A case study of a palm-oil mill plant
title_sort multielemental analysis of an industrial source emission by nuetron activation analysis : a case study of a palm-oil mill plant
publishDate 1987
url http://eprints.utm.my/id/eprint/3785/1/SKMBT_60007061915300.pdf
http://eprints.utm.my/id/eprint/3785/
_version_ 1643643890326044672
score 13.211869