A low cost and high speed electrical capacitance tomography system design

Electrical capacitance tomography system is a system which can be used for imaging industrial multi-component processes involving non-conducting fluids in pipelines. In order to make an ECT system applicable in all kinds of industries, the cost factor of building an ECT system is essential. In this...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Rahim, Ruzairi, Zhen, Cong Tee, Fazalul Rahiman, Mohd. Hafiz, Pusppanathan, Jayasuman
Format: Article
Published: International Frequency Sensors Association 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/37011/
http://www.sensorsportal.com/HTML/DIGEST/P_585.htm
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.37011
record_format eprints
spelling my.utm.370112018-09-30T08:15:29Z http://eprints.utm.my/id/eprint/37011/ A low cost and high speed electrical capacitance tomography system design Abdul Rahim, Ruzairi Zhen, Cong Tee Fazalul Rahiman, Mohd. Hafiz Pusppanathan, Jayasuman TK Electrical engineering. Electronics Nuclear engineering Electrical capacitance tomography system is a system which can be used for imaging industrial multi-component processes involving non-conducting fluids in pipelines. In order to make an ECT system applicable in all kinds of industries, the cost factor of building an ECT system is essential. In this research, we focus on reducing the cost of the system while not affecting the quality of the results. In the past, most of the researches in tomography system have concentrated more on the design of the sensor, and use DAS card as the interface to the PC. This will increase the cost of the system. In this case, the cost of the data acquisition system will be needed to be taken into consideration. To develop a low cost and fast data acquisition system, a Universal Serial Bus (USB) is found to be the most ideal technology. In order to further reduce the cost of the ECT system, a very low cost material, aluminium plates are used as the electrodes of the system. The information obtained in the PC will be reconstructed using iterative algorithm in order to obtain a precise image of the flow in the pipeline. The information obtained from the system will be useful for the purpose of controlling the flow in the pipeline. International Frequency Sensors Association 2010-03 Article PeerReviewed Abdul Rahim, Ruzairi and Zhen, Cong Tee and Fazalul Rahiman, Mohd. Hafiz and Pusppanathan, Jayasuman (2010) A low cost and high speed electrical capacitance tomography system design. Sensors & Transducers Journal, 114 (3). pp. 83-101. ISSN 2306-8515 (Print); 1726-5479 (Electronic) http://www.sensorsportal.com/HTML/DIGEST/P_585.htm
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abdul Rahim, Ruzairi
Zhen, Cong Tee
Fazalul Rahiman, Mohd. Hafiz
Pusppanathan, Jayasuman
A low cost and high speed electrical capacitance tomography system design
description Electrical capacitance tomography system is a system which can be used for imaging industrial multi-component processes involving non-conducting fluids in pipelines. In order to make an ECT system applicable in all kinds of industries, the cost factor of building an ECT system is essential. In this research, we focus on reducing the cost of the system while not affecting the quality of the results. In the past, most of the researches in tomography system have concentrated more on the design of the sensor, and use DAS card as the interface to the PC. This will increase the cost of the system. In this case, the cost of the data acquisition system will be needed to be taken into consideration. To develop a low cost and fast data acquisition system, a Universal Serial Bus (USB) is found to be the most ideal technology. In order to further reduce the cost of the ECT system, a very low cost material, aluminium plates are used as the electrodes of the system. The information obtained in the PC will be reconstructed using iterative algorithm in order to obtain a precise image of the flow in the pipeline. The information obtained from the system will be useful for the purpose of controlling the flow in the pipeline.
format Article
author Abdul Rahim, Ruzairi
Zhen, Cong Tee
Fazalul Rahiman, Mohd. Hafiz
Pusppanathan, Jayasuman
author_facet Abdul Rahim, Ruzairi
Zhen, Cong Tee
Fazalul Rahiman, Mohd. Hafiz
Pusppanathan, Jayasuman
author_sort Abdul Rahim, Ruzairi
title A low cost and high speed electrical capacitance tomography system design
title_short A low cost and high speed electrical capacitance tomography system design
title_full A low cost and high speed electrical capacitance tomography system design
title_fullStr A low cost and high speed electrical capacitance tomography system design
title_full_unstemmed A low cost and high speed electrical capacitance tomography system design
title_sort low cost and high speed electrical capacitance tomography system design
publisher International Frequency Sensors Association
publishDate 2010
url http://eprints.utm.my/id/eprint/37011/
http://www.sensorsportal.com/HTML/DIGEST/P_585.htm
_version_ 1643650060092702720
score 13.18916