Almost half of the total energy used today is consumed in buildings. In the tropical climate, air-conditioning a housing unit takes much of the energy bill. Malaysia is no exception. Malaysian double storey terrace housing is popular among developers and buyers. Surveys have shown that housing occup...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd. Ghazali, Normah, Lau Lau, Kwan Yiew, Mohd.Yusoff, S.
Format: Book Section
Published: American Institute of Physics 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/36051/
http://dx.doi.org/10.1063/1.4704257
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.36051
record_format eprints
spelling my.utm.360512017-02-02T05:57:04Z http://eprints.utm.my/id/eprint/36051/ Thermal analysis of Malaysian double storey housing - low/medium cost unit Mohd. Ghazali, Normah Lau Lau, Kwan Yiew Mohd.Yusoff, S. TJ Mechanical engineering and machinery Almost half of the total energy used today is consumed in buildings. In the tropical climate, air-conditioning a housing unit takes much of the energy bill. Malaysia is no exception. Malaysian double storey terrace housing is popular among developers and buyers. Surveys have shown that housing occupants are much dissatisfied with the thermal comfort and artificial cooling is often sought. The objective of this study is to assess the thermal comfort of the low and medium-cost double storey housing in the area surrounding Universiti Teknologi Malaysia. A simulation program using the Weighting Factor Method calculates the heat transfer interaction, temperature distribution, and PMV level in three types of housing units in relation to the size. Fanger's PMV model based on ISO Standard 7730 is used here because it accounts for all parameters that affect the thermal sensation of a human within its equation. Results showed that both the low and medium-cost housing units studied are out of the comfortable range described by ASHRAE Standard 55 with the units all complied with the local bylaws. In view of the uncertainties in energy supply, future housing units should consider natural ventilation as part of the passive energy management. American Institute of Physics 2012 Book Section PeerReviewed Mohd. Ghazali, Normah and Lau Lau, Kwan Yiew and Mohd.Yusoff, S. (2012) Thermal analysis of Malaysian double storey housing - low/medium cost unit. In: AIP Conference Proceedings. American Institute of Physics, Maryland, USA, pp. 513-520. ISBN 978-073541032-9 http://dx.doi.org/10.1063/1.4704257 DOI:10.1063/1.4704257
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Mohd. Ghazali, Normah
Lau Lau, Kwan Yiew
Mohd.Yusoff, S.
Thermal analysis of Malaysian double storey housing - low/medium cost unit
description Almost half of the total energy used today is consumed in buildings. In the tropical climate, air-conditioning a housing unit takes much of the energy bill. Malaysia is no exception. Malaysian double storey terrace housing is popular among developers and buyers. Surveys have shown that housing occupants are much dissatisfied with the thermal comfort and artificial cooling is often sought. The objective of this study is to assess the thermal comfort of the low and medium-cost double storey housing in the area surrounding Universiti Teknologi Malaysia. A simulation program using the Weighting Factor Method calculates the heat transfer interaction, temperature distribution, and PMV level in three types of housing units in relation to the size. Fanger's PMV model based on ISO Standard 7730 is used here because it accounts for all parameters that affect the thermal sensation of a human within its equation. Results showed that both the low and medium-cost housing units studied are out of the comfortable range described by ASHRAE Standard 55 with the units all complied with the local bylaws. In view of the uncertainties in energy supply, future housing units should consider natural ventilation as part of the passive energy management.
format Book Section
author Mohd. Ghazali, Normah
Lau Lau, Kwan Yiew
Mohd.Yusoff, S.
author_facet Mohd. Ghazali, Normah
Lau Lau, Kwan Yiew
Mohd.Yusoff, S.
author_sort Mohd. Ghazali, Normah
title Thermal analysis of Malaysian double storey housing - low/medium cost unit
title_short Thermal analysis of Malaysian double storey housing - low/medium cost unit
title_full Thermal analysis of Malaysian double storey housing - low/medium cost unit
title_fullStr Thermal analysis of Malaysian double storey housing - low/medium cost unit
title_full_unstemmed Thermal analysis of Malaysian double storey housing - low/medium cost unit
title_sort thermal analysis of malaysian double storey housing - low/medium cost unit
publisher American Institute of Physics
publishDate 2012
url http://eprints.utm.my/id/eprint/36051/
http://dx.doi.org/10.1063/1.4704257
_version_ 1643649889574322176
score 13.160551