The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources

The phenomenon of instability is a major concern in DC power system. This phenomenon is contributed by the undesirable interaction between converter sourceload as well as the behaviour of the power electronic loads which behave as a constant power load. This phenomenon occurs since each converter ha...

Full description

Saved in:
Bibliographic Details
Main Author: Halim, Mohd Jundullah
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/34700/5/MohdJundullahHalimMFKE2013.pdf
http://eprints.utm.my/id/eprint/34700/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:69723?site_name=Restricted Repository
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.34700
record_format eprints
spelling my.utm.347002017-09-11T04:05:14Z http://eprints.utm.my/id/eprint/34700/ The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources Halim, Mohd Jundullah TK Electrical engineering. Electronics Nuclear engineering The phenomenon of instability is a major concern in DC power system. This phenomenon is contributed by the undesirable interaction between converter sourceload as well as the behaviour of the power electronic loads which behave as a constant power load. This phenomenon occurs since each converter has its internal control function to regulate the output voltage. As a consequence, the converter tends to draw a constant power which produces negative incremental input impedance within its bandwidth, in which can lead the instability in the DC power system. The effect of constant power load to a DC power system driven by photovoltaic (PV), combination of wind and thyristor rectifier and also linear sources have been examined in this project. The effects of constant power load (CPL) to a DC power system was extensively reviewed and examined through simulation using MATLAB simulation software. The higher the power level of CPL used, more severe effects on the DC bus system is observed especially when it been driven by the wind energy sources. Simple compensation method using RC parallel passive damping network was proposed and the simulation on a DC power system driven by linear sources shows that the system managed to gain stability under steady state condition. 2013-01 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/34700/5/MohdJundullahHalimMFKE2013.pdf Halim, Mohd Jundullah (2013) The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources. Masters thesis, Universiti Teknologi Malaysia, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:69723?site_name=Restricted Repository
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Halim, Mohd Jundullah
The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources
description The phenomenon of instability is a major concern in DC power system. This phenomenon is contributed by the undesirable interaction between converter sourceload as well as the behaviour of the power electronic loads which behave as a constant power load. This phenomenon occurs since each converter has its internal control function to regulate the output voltage. As a consequence, the converter tends to draw a constant power which produces negative incremental input impedance within its bandwidth, in which can lead the instability in the DC power system. The effect of constant power load to a DC power system driven by photovoltaic (PV), combination of wind and thyristor rectifier and also linear sources have been examined in this project. The effects of constant power load (CPL) to a DC power system was extensively reviewed and examined through simulation using MATLAB simulation software. The higher the power level of CPL used, more severe effects on the DC bus system is observed especially when it been driven by the wind energy sources. Simple compensation method using RC parallel passive damping network was proposed and the simulation on a DC power system driven by linear sources shows that the system managed to gain stability under steady state condition.
format Thesis
author Halim, Mohd Jundullah
author_facet Halim, Mohd Jundullah
author_sort Halim, Mohd Jundullah
title The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources
title_short The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources
title_full The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources
title_fullStr The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources
title_full_unstemmed The study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources
title_sort study on the impact of constant power load to a direct current power system driven by photovoltaic, wind thyristor rectifier and liner sources
publishDate 2013
url http://eprints.utm.my/id/eprint/34700/5/MohdJundullahHalimMFKE2013.pdf
http://eprints.utm.my/id/eprint/34700/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:69723?site_name=Restricted Repository
_version_ 1643649649942200320