Application of component method on partial strength connections connected by thick plate between column flanges

Traditional beam connections to the minor axis of a column have relatively low strength and stiffness. A modified detail, using a plate welded between the toes of the column flange - referred to as a toe plate connection - is examined in this paper. The results of an experimental investigation for b...

Full description

Saved in:
Bibliographic Details
Main Authors: Md. Tahir, Mahmood, Juki, Irwan, Ishak, Mohd. Yunus, Mohammad, Shahrin, Z. Awang, Abdullah
Format: Conference or Workshop Item
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/34352/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.34352
record_format eprints
spelling my.utm.343522017-09-06T08:19:16Z http://eprints.utm.my/id/eprint/34352/ Application of component method on partial strength connections connected by thick plate between column flanges Md. Tahir, Mahmood Juki, Irwan Ishak, Mohd. Yunus Mohammad, Shahrin Z. Awang, Abdullah TA Engineering (General). Civil engineering (General) Traditional beam connections to the minor axis of a column have relatively low strength and stiffness. A modified detail, using a plate welded between the toes of the column flange - referred to as a toe plate connection - is examined in this paper. The results of an experimental investigation for both flush and extended end-plate connections connected to a 25 mm thick end-plate are presented. The tests are complemented by finite element modelling which compares very well with the test observations. The results show a significant increase in both moment resistance and initial stiffness for this connection detail compared with connections made directly to the column web. This offers the prospect of more optimal solutions taking advantage of partial strength frame design for the minor axis as well as major axis. 2012 Conference or Workshop Item PeerReviewed Md. Tahir, Mahmood and Juki, Irwan and Ishak, Mohd. Yunus and Mohammad, Shahrin and Z. Awang, Abdullah (2012) Application of component method on partial strength connections connected by thick plate between column flanges. In: Conference.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Md. Tahir, Mahmood
Juki, Irwan
Ishak, Mohd. Yunus
Mohammad, Shahrin
Z. Awang, Abdullah
Application of component method on partial strength connections connected by thick plate between column flanges
description Traditional beam connections to the minor axis of a column have relatively low strength and stiffness. A modified detail, using a plate welded between the toes of the column flange - referred to as a toe plate connection - is examined in this paper. The results of an experimental investigation for both flush and extended end-plate connections connected to a 25 mm thick end-plate are presented. The tests are complemented by finite element modelling which compares very well with the test observations. The results show a significant increase in both moment resistance and initial stiffness for this connection detail compared with connections made directly to the column web. This offers the prospect of more optimal solutions taking advantage of partial strength frame design for the minor axis as well as major axis.
format Conference or Workshop Item
author Md. Tahir, Mahmood
Juki, Irwan
Ishak, Mohd. Yunus
Mohammad, Shahrin
Z. Awang, Abdullah
author_facet Md. Tahir, Mahmood
Juki, Irwan
Ishak, Mohd. Yunus
Mohammad, Shahrin
Z. Awang, Abdullah
author_sort Md. Tahir, Mahmood
title Application of component method on partial strength connections connected by thick plate between column flanges
title_short Application of component method on partial strength connections connected by thick plate between column flanges
title_full Application of component method on partial strength connections connected by thick plate between column flanges
title_fullStr Application of component method on partial strength connections connected by thick plate between column flanges
title_full_unstemmed Application of component method on partial strength connections connected by thick plate between column flanges
title_sort application of component method on partial strength connections connected by thick plate between column flanges
publishDate 2012
url http://eprints.utm.my/id/eprint/34352/
_version_ 1643649564415098880
score 13.18916