Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples

Transformer is the main element of a power system. The insulation of transformer has to be maintained and do regular routine service in order to deliver power effectively. Recently dielectric measurement has been used for assessing the condition of oil/paper insulation. There are several nondestruct...

Full description

Saved in:
Bibliographic Details
Main Authors: Ramachandiran, Vithya, Muhamad, Nor Asiah, Talib, Mohd. Aizam
Format: Conference or Workshop Item
Published: 2012
Online Access:http://eprints.utm.my/id/eprint/34252/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.34252
record_format eprints
spelling my.utm.342522017-09-10T06:18:09Z http://eprints.utm.my/id/eprint/34252/ Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples Ramachandiran, Vithya Muhamad, Nor Asiah Talib, Mohd. Aizam Transformer is the main element of a power system. The insulation of transformer has to be maintained and do regular routine service in order to deliver power effectively. Recently dielectric measurement has been used for assessing the condition of oil/paper insulation. There are several nondestructive dielectric testing method for determining the conductivity and moisture content of insulation materials in a transformer. This research utilizes one of the dielectric methods which are Polarization and Depolarization Current (PDC) analysis in order to identify insulation condition of mineral oil. This paper presents the classifications of breakdown, overheating and partial discharge faults in mineral-oil insulated transformer by using PDC measurement data analysis. The classification is based on the data pattern and statistical analysis. The samples data was obtained from laboratory and from site testing. An analysis result shows that different type of faults will give different outcome to the PDC pattern and as well as statistical data. Based on the result, these three types of faults can be used to identify the insulation condition by using PDC measurement data analysis. 2012 Conference or Workshop Item PeerReviewed Ramachandiran, Vithya and Muhamad, Nor Asiah and Talib, Mohd. Aizam (2012) Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples. In: 2nd International Conference on Engineering and Technology Innovation 2012 (ICETI2012).
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
description Transformer is the main element of a power system. The insulation of transformer has to be maintained and do regular routine service in order to deliver power effectively. Recently dielectric measurement has been used for assessing the condition of oil/paper insulation. There are several nondestructive dielectric testing method for determining the conductivity and moisture content of insulation materials in a transformer. This research utilizes one of the dielectric methods which are Polarization and Depolarization Current (PDC) analysis in order to identify insulation condition of mineral oil. This paper presents the classifications of breakdown, overheating and partial discharge faults in mineral-oil insulated transformer by using PDC measurement data analysis. The classification is based on the data pattern and statistical analysis. The samples data was obtained from laboratory and from site testing. An analysis result shows that different type of faults will give different outcome to the PDC pattern and as well as statistical data. Based on the result, these three types of faults can be used to identify the insulation condition by using PDC measurement data analysis.
format Conference or Workshop Item
author Ramachandiran, Vithya
Muhamad, Nor Asiah
Talib, Mohd. Aizam
spellingShingle Ramachandiran, Vithya
Muhamad, Nor Asiah
Talib, Mohd. Aizam
Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples
author_facet Ramachandiran, Vithya
Muhamad, Nor Asiah
Talib, Mohd. Aizam
author_sort Ramachandiran, Vithya
title Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples
title_short Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples
title_full Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples
title_fullStr Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples
title_full_unstemmed Transformer faults classification based on Polarization And Depolarization Current (PDC) measurement test data on mineral oil samples
title_sort transformer faults classification based on polarization and depolarization current (pdc) measurement test data on mineral oil samples
publishDate 2012
url http://eprints.utm.my/id/eprint/34252/
_version_ 1643649546808459264
score 13.160551