The effects of tapered sleeve in improving the achorage bond of reinforcement bar

This research examine on the effectiveness of tapered sleeve connector in providing confinement effect to embedded reinforcement bar. The objectives of the investigation are to study the bond mechanism of grouted sleeve connector and to study the effects of confinement provided by the grouted sleeve...

Full description

Saved in:
Bibliographic Details
Main Author: Pamela, Adeline Lo
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/33146/1/PamelaAdelineLoMFKA2013.pdf
http://eprints.utm.my/id/eprint/33146/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.33146
record_format eprints
spelling my.utm.331462017-09-14T06:45:52Z http://eprints.utm.my/id/eprint/33146/ The effects of tapered sleeve in improving the achorage bond of reinforcement bar Pamela, Adeline Lo TA Engineering (General). Civil engineering (General) This research examine on the effectiveness of tapered sleeve connector in providing confinement effect to embedded reinforcement bar. The objectives of the investigation are to study the bond mechanism of grouted sleeve connector and to study the effects of confinement provided by the grouted sleeve connector. Two different configurations (welded bar sleeve and tapered sleeve) of sleeve connector were used in this study. Various sleeve diameters were used in this research to study their effects on the bond mechanism. The bond failure progression inside the grouted sleeve connector was observed visually as halved welded steel bar connector and tapered head connector were used. The experimental works consisted two phases where phase I was the testing of plain grouted sleeve. Phase II involved the testing steel fibre reinforced grout sleeve. Steel fibres of 0%, 0.5%, 0.75% and 1.0% were introduced to the connector in a way so the grout inside the connector will exhibit post-cracking behaviour. Pull-out tests were carried out and it was observed that the performance of tapered sleeve was better than welded bar sleeve due to higher confinement level. The provision of sufficient confinement stress able to delay the development of splitting cracks. The test result showed that welded bar sleeve was governed by splitting failure mode, whereas tapered sleeve failed in pull-out failure mode. 2013-01 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/33146/1/PamelaAdelineLoMFKA2013.pdf Pamela, Adeline Lo (2013) The effects of tapered sleeve in improving the achorage bond of reinforcement bar. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Pamela, Adeline Lo
The effects of tapered sleeve in improving the achorage bond of reinforcement bar
description This research examine on the effectiveness of tapered sleeve connector in providing confinement effect to embedded reinforcement bar. The objectives of the investigation are to study the bond mechanism of grouted sleeve connector and to study the effects of confinement provided by the grouted sleeve connector. Two different configurations (welded bar sleeve and tapered sleeve) of sleeve connector were used in this study. Various sleeve diameters were used in this research to study their effects on the bond mechanism. The bond failure progression inside the grouted sleeve connector was observed visually as halved welded steel bar connector and tapered head connector were used. The experimental works consisted two phases where phase I was the testing of plain grouted sleeve. Phase II involved the testing steel fibre reinforced grout sleeve. Steel fibres of 0%, 0.5%, 0.75% and 1.0% were introduced to the connector in a way so the grout inside the connector will exhibit post-cracking behaviour. Pull-out tests were carried out and it was observed that the performance of tapered sleeve was better than welded bar sleeve due to higher confinement level. The provision of sufficient confinement stress able to delay the development of splitting cracks. The test result showed that welded bar sleeve was governed by splitting failure mode, whereas tapered sleeve failed in pull-out failure mode.
format Thesis
author Pamela, Adeline Lo
author_facet Pamela, Adeline Lo
author_sort Pamela, Adeline Lo
title The effects of tapered sleeve in improving the achorage bond of reinforcement bar
title_short The effects of tapered sleeve in improving the achorage bond of reinforcement bar
title_full The effects of tapered sleeve in improving the achorage bond of reinforcement bar
title_fullStr The effects of tapered sleeve in improving the achorage bond of reinforcement bar
title_full_unstemmed The effects of tapered sleeve in improving the achorage bond of reinforcement bar
title_sort effects of tapered sleeve in improving the achorage bond of reinforcement bar
publishDate 2013
url http://eprints.utm.my/id/eprint/33146/1/PamelaAdelineLoMFKA2013.pdf
http://eprints.utm.my/id/eprint/33146/
_version_ 1643649244696936448
score 13.18916