An automatic load shedding scheme for titan petrochemical industrial plant

In view of increasing in load demand, dependence on the reliable electricity supply and deregulation have forced the need for load shedding to maintain the power system stability and provide good system performance. Under normal operation, the total system generation is the sum of total load and los...

Full description

Saved in:
Bibliographic Details
Main Author: Krishnan, Chandran
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/33086/5/ChandranKrishnanMFKE2013.pdf
http://eprints.utm.my/id/eprint/33086/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.33086
record_format eprints
spelling my.utm.330862017-09-12T07:54:00Z http://eprints.utm.my/id/eprint/33086/ An automatic load shedding scheme for titan petrochemical industrial plant Krishnan, Chandran TK Electrical engineering. Electronics Nuclear engineering In view of increasing in load demand, dependence on the reliable electricity supply and deregulation have forced the need for load shedding to maintain the power system stability and provide good system performance. Under normal operation, the total system generation is the sum of total load and losses in the system. The frequency variation of the power system depends on the active power. On occurrence of any disturbance in the power system, there is imbalance between the generation and load. The difference between the generation and load active power causes a sudden change in the system frequency. A higher deviation in the frequency can affect the performance of the power system and cause overall system to collapse. This project proposes fixed and underfrequency load shedding scheme for TITAN Petrochemical during disturbance in power system. In order to control the frequency drop in severe disturbance, appropriate amount of system load is intentionally and automatically curtailed. In order to improve the response time, accurately predicting the system disturbance and follow with calculating the amount of load to be shed, are very essential. PSCAD I EMTDC software is used to analyze the performance of the designed model and load shedding steps. The result shows that designed load shedding scheme maintained power system performance as such distribution voltage and frequency are within permissible operating limit. 2013-01 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/33086/5/ChandranKrishnanMFKE2013.pdf Krishnan, Chandran (2013) An automatic load shedding scheme for titan petrochemical industrial plant. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Krishnan, Chandran
An automatic load shedding scheme for titan petrochemical industrial plant
description In view of increasing in load demand, dependence on the reliable electricity supply and deregulation have forced the need for load shedding to maintain the power system stability and provide good system performance. Under normal operation, the total system generation is the sum of total load and losses in the system. The frequency variation of the power system depends on the active power. On occurrence of any disturbance in the power system, there is imbalance between the generation and load. The difference between the generation and load active power causes a sudden change in the system frequency. A higher deviation in the frequency can affect the performance of the power system and cause overall system to collapse. This project proposes fixed and underfrequency load shedding scheme for TITAN Petrochemical during disturbance in power system. In order to control the frequency drop in severe disturbance, appropriate amount of system load is intentionally and automatically curtailed. In order to improve the response time, accurately predicting the system disturbance and follow with calculating the amount of load to be shed, are very essential. PSCAD I EMTDC software is used to analyze the performance of the designed model and load shedding steps. The result shows that designed load shedding scheme maintained power system performance as such distribution voltage and frequency are within permissible operating limit.
format Thesis
author Krishnan, Chandran
author_facet Krishnan, Chandran
author_sort Krishnan, Chandran
title An automatic load shedding scheme for titan petrochemical industrial plant
title_short An automatic load shedding scheme for titan petrochemical industrial plant
title_full An automatic load shedding scheme for titan petrochemical industrial plant
title_fullStr An automatic load shedding scheme for titan petrochemical industrial plant
title_full_unstemmed An automatic load shedding scheme for titan petrochemical industrial plant
title_sort automatic load shedding scheme for titan petrochemical industrial plant
publishDate 2013
url http://eprints.utm.my/id/eprint/33086/5/ChandranKrishnanMFKE2013.pdf
http://eprints.utm.my/id/eprint/33086/
_version_ 1643649226620534784
score 13.160551