Performance of generator negative-sequence protection during single-phase fault

Negative-sequence current is a component that resulted from unbalance conditions that occur in the system. Theoretically, problems caused by the negativesequence current are rare and can be ignored, but in reality the presence of negative sequence current which exceeds the permitted level will affec...

Full description

Saved in:
Bibliographic Details
Main Author: Ali Mohd. Jobran, Junaidah
Format: Thesis
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/32411/5/JunaidahAliMohdJobranMFKE2012.pdf
http://eprints.utm.my/id/eprint/32411/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.32411
record_format eprints
spelling my.utm.324112018-05-27T07:44:33Z http://eprints.utm.my/id/eprint/32411/ Performance of generator negative-sequence protection during single-phase fault Ali Mohd. Jobran, Junaidah TK Electrical engineering. Electronics Nuclear engineering Negative-sequence current is a component that resulted from unbalance conditions that occur in the system. Theoretically, problems caused by the negativesequence current are rare and can be ignored, but in reality the presence of negative sequence current which exceeds the permitted level will affect the performance of the generator. Therefore, some utility companies tend to adopt more passive method by tripping and separating the generator from the system if negative-sequence current is higher than the predefined level. However, tripping of major generation facilities may create social, security and economic problem. In order to protect the generator from negative-sequence current, there are many methods can be used as the negativesequence protection. One of the methods is using negative-sequence impedance directional element. In this project, several types of unbalanced conditions are tested on the parallel system, which have four main parts to be completed namely threephase parallel line system, breaker control, fault control and negative-sequence protection system. The design circuit is constructed and simulated using PSCAD/EMTDC software, to check the comparison between the generator with negative-sequence protection and generator without negative-sequence protection. The data are analyzed based on the rms value of the generator, to evaluate the generator’s performance during unbalanced conditions. From the result, it shown that the performance of the generator with negative-sequence protection is stable with very small value of negative-sequence current compared to the generator without negative-sequence protection. In the end, new techniques are suggested as the alternatives to improve the performance of the generator. 2012 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/32411/5/JunaidahAliMohdJobranMFKE2012.pdf Ali Mohd. Jobran, Junaidah (2012) Performance of generator negative-sequence protection during single-phase fault. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ali Mohd. Jobran, Junaidah
Performance of generator negative-sequence protection during single-phase fault
description Negative-sequence current is a component that resulted from unbalance conditions that occur in the system. Theoretically, problems caused by the negativesequence current are rare and can be ignored, but in reality the presence of negative sequence current which exceeds the permitted level will affect the performance of the generator. Therefore, some utility companies tend to adopt more passive method by tripping and separating the generator from the system if negative-sequence current is higher than the predefined level. However, tripping of major generation facilities may create social, security and economic problem. In order to protect the generator from negative-sequence current, there are many methods can be used as the negativesequence protection. One of the methods is using negative-sequence impedance directional element. In this project, several types of unbalanced conditions are tested on the parallel system, which have four main parts to be completed namely threephase parallel line system, breaker control, fault control and negative-sequence protection system. The design circuit is constructed and simulated using PSCAD/EMTDC software, to check the comparison between the generator with negative-sequence protection and generator without negative-sequence protection. The data are analyzed based on the rms value of the generator, to evaluate the generator’s performance during unbalanced conditions. From the result, it shown that the performance of the generator with negative-sequence protection is stable with very small value of negative-sequence current compared to the generator without negative-sequence protection. In the end, new techniques are suggested as the alternatives to improve the performance of the generator.
format Thesis
author Ali Mohd. Jobran, Junaidah
author_facet Ali Mohd. Jobran, Junaidah
author_sort Ali Mohd. Jobran, Junaidah
title Performance of generator negative-sequence protection during single-phase fault
title_short Performance of generator negative-sequence protection during single-phase fault
title_full Performance of generator negative-sequence protection during single-phase fault
title_fullStr Performance of generator negative-sequence protection during single-phase fault
title_full_unstemmed Performance of generator negative-sequence protection during single-phase fault
title_sort performance of generator negative-sequence protection during single-phase fault
publishDate 2012
url http://eprints.utm.my/id/eprint/32411/5/JunaidahAliMohdJobranMFKE2012.pdf
http://eprints.utm.my/id/eprint/32411/
_version_ 1643649031757365248
score 13.160551