Visual inspection and detail evaluation for earthquake disaster mitigation

Malaysia is considered as a very low seismic region country. However countries that border Malaysia such as Indonesia and Philippines are the two most seismically active countries with frequent earthquakes. The close proximity of these countries means that Malaysia is prone to risk of distance earth...

Full description

Saved in:
Bibliographic Details
Main Authors: Zakaria, Rozana, Ramli, Mohd. Zamri, Choo, Kok Wah
Format: Book Section
Published: Trans Tech Publications 2011
Subjects:
Online Access:http://eprints.utm.my/id/eprint/29912/
http://dx.doi.org/10.4028/www.scientific.net/AMM.90-93.3131
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.29912
record_format eprints
spelling my.utm.299122017-02-05T00:12:05Z http://eprints.utm.my/id/eprint/29912/ Visual inspection and detail evaluation for earthquake disaster mitigation Zakaria, Rozana Ramli, Mohd. Zamri Choo, Kok Wah TA Engineering (General). Civil engineering (General) Malaysia is considered as a very low seismic region country. However countries that border Malaysia such as Indonesia and Philippines are the two most seismically active countries with frequent earthquakes. The close proximity of these countries means that Malaysia is prone to risk of distance earthquakes. As such, anticipated problem associated with earthquakes must be dealt with. There is several problems expected need to be justified in this disaster phenomenon. Area of higher risk to be affected by earthquake need to be identified. To date, many building in Malaysia are not designed to withstand seismic load which means that they are susceptible to collapse in the event of earthquakes. School buildings contain large numbers of public user during most of the times. A sustainable approach of visual assessment and detailed analysis are needed to ensure the school building sustainability towards an earthquake threat. An ATC-21 evaluation and a finite element analysis were performed on a 4 storey standard school building in order to evaluate its performance should it be subjected to seismic waves. Results from the analysis were used to compare with the structures actual capacity and a potential improvement to the building can be identified. The assessment methods engaged no destructive in-situ test and the cost involved in the assessment are kept to a minimum. The final outcome of the study produces a guideline and database that served as a potential maintenance proposal and reference for engineering community in the future. Trans Tech Publications 2011 Book Section PeerReviewed Zakaria, Rozana and Ramli, Mohd. Zamri and Choo, Kok Wah (2011) Visual inspection and detail evaluation for earthquake disaster mitigation. In: Applied Mechanics and Materials. Trans Tech Publications, Switzerland, pp. 3131-3134. ISBN 978-303785242-2 http://dx.doi.org/10.4028/www.scientific.net/AMM.90-93.3131 10.4028/www.scientific.net/AMM.90-93.3131
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Zakaria, Rozana
Ramli, Mohd. Zamri
Choo, Kok Wah
Visual inspection and detail evaluation for earthquake disaster mitigation
description Malaysia is considered as a very low seismic region country. However countries that border Malaysia such as Indonesia and Philippines are the two most seismically active countries with frequent earthquakes. The close proximity of these countries means that Malaysia is prone to risk of distance earthquakes. As such, anticipated problem associated with earthquakes must be dealt with. There is several problems expected need to be justified in this disaster phenomenon. Area of higher risk to be affected by earthquake need to be identified. To date, many building in Malaysia are not designed to withstand seismic load which means that they are susceptible to collapse in the event of earthquakes. School buildings contain large numbers of public user during most of the times. A sustainable approach of visual assessment and detailed analysis are needed to ensure the school building sustainability towards an earthquake threat. An ATC-21 evaluation and a finite element analysis were performed on a 4 storey standard school building in order to evaluate its performance should it be subjected to seismic waves. Results from the analysis were used to compare with the structures actual capacity and a potential improvement to the building can be identified. The assessment methods engaged no destructive in-situ test and the cost involved in the assessment are kept to a minimum. The final outcome of the study produces a guideline and database that served as a potential maintenance proposal and reference for engineering community in the future.
format Book Section
author Zakaria, Rozana
Ramli, Mohd. Zamri
Choo, Kok Wah
author_facet Zakaria, Rozana
Ramli, Mohd. Zamri
Choo, Kok Wah
author_sort Zakaria, Rozana
title Visual inspection and detail evaluation for earthquake disaster mitigation
title_short Visual inspection and detail evaluation for earthquake disaster mitigation
title_full Visual inspection and detail evaluation for earthquake disaster mitigation
title_fullStr Visual inspection and detail evaluation for earthquake disaster mitigation
title_full_unstemmed Visual inspection and detail evaluation for earthquake disaster mitigation
title_sort visual inspection and detail evaluation for earthquake disaster mitigation
publisher Trans Tech Publications
publishDate 2011
url http://eprints.utm.my/id/eprint/29912/
http://dx.doi.org/10.4028/www.scientific.net/AMM.90-93.3131
_version_ 1643648403779878912
score 13.214268