Arcing fault detection for a double busbar metal enclosed switchgear

Arcing fault issues have increased concern and awareness of many people in different background. The effect it causes leads to the development of arc fault detectors. Arc fault detector is associated with overcurrent relay in older switchgear system to improve speed performance of switchgear protect...

Full description

Saved in:
Bibliographic Details
Main Authors: Ismail, Nur'Ain Maiza, Mohd. Zin, Abdullah Asuhaimi, A. Karim, S. P.
Format: Article
Published: Praise Worthy Prize S.r.l 2011
Subjects:
Online Access:http://eprints.utm.my/id/eprint/28806/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.28806
record_format eprints
spelling my.utm.288062020-10-22T03:59:04Z http://eprints.utm.my/id/eprint/28806/ Arcing fault detection for a double busbar metal enclosed switchgear Ismail, Nur'Ain Maiza Mohd. Zin, Abdullah Asuhaimi A. Karim, S. P. TK Electrical engineering. Electronics Nuclear engineering Arcing fault issues have increased concern and awareness of many people in different background. The effect it causes leads to the development of arc fault detectors. Arc fault detector is associated with overcurrent relay in older switchgear system to improve speed performance of switchgear protection system. In this paper, a new design of arc fault detector for double busbar metal-enclosed medium voltage switchgear is introduced to develop a better arc fault detection in terms of selectivity. A position sensor is associated concurrently with light and current detector in providing a tripping signal to the corresponding circuit breaker. The circuit is designed using Boolean algebra approached and simulated in MATLAB Simulink. Simulation results are observed to verify the performance of the arc fault detector in terms of solving false tripping problems. Praise Worthy Prize S.r.l 2011-02 Article PeerReviewed Ismail, Nur'Ain Maiza and Mohd. Zin, Abdullah Asuhaimi and A. Karim, S. P. (2011) Arcing fault detection for a double busbar metal enclosed switchgear. International Review on Modelling and Simulations, 4 (1). pp. 207-213. ISSN 1974-9821
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ismail, Nur'Ain Maiza
Mohd. Zin, Abdullah Asuhaimi
A. Karim, S. P.
Arcing fault detection for a double busbar metal enclosed switchgear
description Arcing fault issues have increased concern and awareness of many people in different background. The effect it causes leads to the development of arc fault detectors. Arc fault detector is associated with overcurrent relay in older switchgear system to improve speed performance of switchgear protection system. In this paper, a new design of arc fault detector for double busbar metal-enclosed medium voltage switchgear is introduced to develop a better arc fault detection in terms of selectivity. A position sensor is associated concurrently with light and current detector in providing a tripping signal to the corresponding circuit breaker. The circuit is designed using Boolean algebra approached and simulated in MATLAB Simulink. Simulation results are observed to verify the performance of the arc fault detector in terms of solving false tripping problems.
format Article
author Ismail, Nur'Ain Maiza
Mohd. Zin, Abdullah Asuhaimi
A. Karim, S. P.
author_facet Ismail, Nur'Ain Maiza
Mohd. Zin, Abdullah Asuhaimi
A. Karim, S. P.
author_sort Ismail, Nur'Ain Maiza
title Arcing fault detection for a double busbar metal enclosed switchgear
title_short Arcing fault detection for a double busbar metal enclosed switchgear
title_full Arcing fault detection for a double busbar metal enclosed switchgear
title_fullStr Arcing fault detection for a double busbar metal enclosed switchgear
title_full_unstemmed Arcing fault detection for a double busbar metal enclosed switchgear
title_sort arcing fault detection for a double busbar metal enclosed switchgear
publisher Praise Worthy Prize S.r.l
publishDate 2011
url http://eprints.utm.my/id/eprint/28806/
_version_ 1681489435555790848
score 13.211869