Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier
A computer programme was developed using Fortran programming language utilizing IBM-PC compatible microcomputers to design a secondary clarifier in a centralised municipal wastewater treatment plant. The programme is used to design the dimension and capacity of four circular secondary clarifiers inc...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Civil Engineering, Universiti Teknologi Malaysia
1996
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/27866/1/AmatSairinDemun1996_DevelopmentOfAComputerProgrammeForTheDesignOfMunicipal.pdf http://eprints.utm.my/id/eprint/27866/ http://www.civil.utm.my/content.php?id=387&cid=204&lang=1 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.27866 |
---|---|
record_format |
eprints |
spelling |
my.utm.278662012-08-10T07:43:27Z http://eprints.utm.my/id/eprint/27866/ Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier Demun, Amat Sairin TA Engineering (General). Civil engineering (General) TC Hydraulic engineering. Ocean engineering A computer programme was developed using Fortran programming language utilizing IBM-PC compatible microcomputers to design a secondary clarifier in a centralised municipal wastewater treatment plant. The programme is used to design the dimension and capacity of four circular secondary clarifiers including the influent and effluent structure to satisfy the specified design criteria such as the detention time, the overflow rate, solid-loading rates and weir loading. The programme was written in a subroutine called from the main programme which also be able to call other subroutines for designing other facilities in the treatment plant. The programme runs successfully given the right input data. The results are easy to interpret and automatically appear either on the computer screen or in an output file Faculty of Civil Engineering, Universiti Teknologi Malaysia 1996 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/27866/1/AmatSairinDemun1996_DevelopmentOfAComputerProgrammeForTheDesignOfMunicipal.pdf Demun, Amat Sairin (1996) Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier. Jurnal Kejuruteraan Awam, 9 (2). pp. 1-13. ISSN 0128-0147 http://www.civil.utm.my/content.php?id=387&cid=204&lang=1 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) TC Hydraulic engineering. Ocean engineering |
spellingShingle |
TA Engineering (General). Civil engineering (General) TC Hydraulic engineering. Ocean engineering Demun, Amat Sairin Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier |
description |
A computer programme was developed using Fortran programming language utilizing IBM-PC compatible microcomputers to design a secondary clarifier in a centralised municipal wastewater treatment plant. The programme is used to design the dimension and capacity of four circular secondary clarifiers including the influent and effluent structure to satisfy the specified design criteria such as the detention time, the overflow rate, solid-loading rates and weir loading. The programme was written in a subroutine called from the main programme which also be able to call other subroutines for designing other facilities in the treatment plant. The programme runs successfully given the right input data. The results are easy to interpret and automatically appear either on the computer screen or in an output file |
format |
Article |
author |
Demun, Amat Sairin |
author_facet |
Demun, Amat Sairin |
author_sort |
Demun, Amat Sairin |
title |
Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier |
title_short |
Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier |
title_full |
Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier |
title_fullStr |
Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier |
title_full_unstemmed |
Development of a computer programme for the design of municipal wastewater treatment facilities Part 5: secondary clarifier |
title_sort |
development of a computer programme for the design of municipal wastewater treatment facilities part 5: secondary clarifier |
publisher |
Faculty of Civil Engineering, Universiti Teknologi Malaysia |
publishDate |
1996 |
url |
http://eprints.utm.my/id/eprint/27866/1/AmatSairinDemun1996_DevelopmentOfAComputerProgrammeForTheDesignOfMunicipal.pdf http://eprints.utm.my/id/eprint/27866/ http://www.civil.utm.my/content.php?id=387&cid=204&lang=1 |
_version_ |
1643647962432143360 |
score |
13.214268 |