Determination of best location of FACTS devices for damping oscillations

This paper proposes a residue factor method to find the optimal location of the FACTS controllers. Three types of FACTS controllers have been considered, which include thyristor-controlled series compensator (TCSC), Static Var compensator (SVC) and unified power flow controller (UPFC). The effective...

Full description

Saved in:
Bibliographic Details
Main Authors: Magaji, Nuraddeen, Mustafa, Mohd. Wazir
Format: Article
Published: Praise Worthy Prize S.r.l. 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/27066/
http://www.praiseworthyprize.com/IREE-latest/IREE_vol_5_n_3.html#Determination_of_Best_Location_of_FACTS_Devices_for_Damping_Oscillations
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.27066
record_format eprints
spelling my.utm.270662018-11-30T07:07:13Z http://eprints.utm.my/id/eprint/27066/ Determination of best location of FACTS devices for damping oscillations Magaji, Nuraddeen Mustafa, Mohd. Wazir TK Electrical engineering. Electronics Nuclear engineering This paper proposes a residue factor method to find the optimal location of the FACTS controllers. Three types of FACTS controllers have been considered, which include thyristor-controlled series compensator (TCSC), Static Var compensator (SVC) and unified power flow controller (UPFC). The effectiveness of this controller depends on its optimal location and proper signal selection in the power system network. The proposed residue factor is based on the relative participation of the parameters of FACTS controller to the critical mode. A simple approach of computing the residue factor has been proposed, which combines the linearised differential algebraic equation model of the power system and the FACTS input and output equations. The placements of FACTS controllers have been obtained for the base case and for the dynamic critical contingences. The effectiveness of the proposed method of placement is demonstrated on 11 bus system and New England 39 Bus system. Praise Worthy Prize S.r.l. 2010-05 Article PeerReviewed Magaji, Nuraddeen and Mustafa, Mohd. Wazir (2010) Determination of best location of FACTS devices for damping oscillations. International Review Of Electrical Engineering-IREE, 5 (3). pp. 1119-1126. ISSN 1827- 6660 http://www.praiseworthyprize.com/IREE-latest/IREE_vol_5_n_3.html#Determination_of_Best_Location_of_FACTS_Devices_for_Damping_Oscillations
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Magaji, Nuraddeen
Mustafa, Mohd. Wazir
Determination of best location of FACTS devices for damping oscillations
description This paper proposes a residue factor method to find the optimal location of the FACTS controllers. Three types of FACTS controllers have been considered, which include thyristor-controlled series compensator (TCSC), Static Var compensator (SVC) and unified power flow controller (UPFC). The effectiveness of this controller depends on its optimal location and proper signal selection in the power system network. The proposed residue factor is based on the relative participation of the parameters of FACTS controller to the critical mode. A simple approach of computing the residue factor has been proposed, which combines the linearised differential algebraic equation model of the power system and the FACTS input and output equations. The placements of FACTS controllers have been obtained for the base case and for the dynamic critical contingences. The effectiveness of the proposed method of placement is demonstrated on 11 bus system and New England 39 Bus system.
format Article
author Magaji, Nuraddeen
Mustafa, Mohd. Wazir
author_facet Magaji, Nuraddeen
Mustafa, Mohd. Wazir
author_sort Magaji, Nuraddeen
title Determination of best location of FACTS devices for damping oscillations
title_short Determination of best location of FACTS devices for damping oscillations
title_full Determination of best location of FACTS devices for damping oscillations
title_fullStr Determination of best location of FACTS devices for damping oscillations
title_full_unstemmed Determination of best location of FACTS devices for damping oscillations
title_sort determination of best location of facts devices for damping oscillations
publisher Praise Worthy Prize S.r.l.
publishDate 2010
url http://eprints.utm.my/id/eprint/27066/
http://www.praiseworthyprize.com/IREE-latest/IREE_vol_5_n_3.html#Determination_of_Best_Location_of_FACTS_Devices_for_Damping_Oscillations
_version_ 1643647939999956992
score 13.209306