Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis
A new breast cancer detection method that is based on tissue bioelectric and acoustic characteristics has been developed by using a hybrid magnetoacoustics method. This method manipulates the interaction between acoustic and magnetic energy upon moving ions inside the breast tissue. Analytical in-vi...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Published: |
World Scientific and Engineering Academy and Society
2010
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/25904/ https://www.researchgate.net/publication/234803238_Hybrid_magnetoacoustic_method_for_breast_tumor_detection_An_in-vivo_and_in-vitro_modelling_and_analysis |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.25904 |
---|---|
record_format |
eprints |
spelling |
my.utm.259042017-02-19T08:29:19Z http://eprints.utm.my/id/eprint/25904/ Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis Mohamad Salim, Maheza Irna Tumiran, Mohammad Azizi Makhtar, Siti Noormiza Rosidi, Bustanur Ariffin, Ismail Ahmad, Abdul Hamid Supriyanto, Eko QH301 Biology A new breast cancer detection method that is based on tissue bioelectric and acoustic characteristics has been developed by using a hybrid magnetoacoustics method. This method manipulates the interaction between acoustic and magnetic energy upon moving ions inside the breast tissue. Analytical in-vivo and in-vitro modelling and analysis on the system performance have been done on normal and pathological mice breast tissue models. Analysis result shows that, hybrid magnetoacoustic method is capable to give unique characteristics between normal and pathological mice breast tissue models especially in in-vitro application. However, additional parameter such as analysis of current distribution in tissue should be taken into account for in-vivo application due to the redundancy of the existing result. World Scientific and Engineering Academy and Society 2010 Article PeerReviewed Mohamad Salim, Maheza Irna and Tumiran, Mohammad Azizi and Makhtar, Siti Noormiza and Rosidi, Bustanur and Ariffin, Ismail and Ahmad, Abdul Hamid and Supriyanto, Eko (2010) Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis. WSEAS Transactions on Information Science and Application, 7 (8). pp. 1048-1057. ISSN 1790-0832 https://www.researchgate.net/publication/234803238_Hybrid_magnetoacoustic_method_for_breast_tumor_detection_An_in-vivo_and_in-vitro_modelling_and_analysis |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
QH301 Biology |
spellingShingle |
QH301 Biology Mohamad Salim, Maheza Irna Tumiran, Mohammad Azizi Makhtar, Siti Noormiza Rosidi, Bustanur Ariffin, Ismail Ahmad, Abdul Hamid Supriyanto, Eko Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis |
description |
A new breast cancer detection method that is based on tissue bioelectric and acoustic characteristics has been developed by using a hybrid magnetoacoustics method. This method manipulates the interaction between acoustic and magnetic energy upon moving ions inside the breast tissue. Analytical in-vivo and in-vitro modelling and analysis on the system performance have been done on normal and pathological mice breast tissue models. Analysis result shows that, hybrid magnetoacoustic method is capable to give unique characteristics between normal and pathological mice breast tissue models especially in in-vitro application. However, additional parameter such as analysis of current distribution in tissue should be taken into account for in-vivo application due to the redundancy of the existing result. |
format |
Article |
author |
Mohamad Salim, Maheza Irna Tumiran, Mohammad Azizi Makhtar, Siti Noormiza Rosidi, Bustanur Ariffin, Ismail Ahmad, Abdul Hamid Supriyanto, Eko |
author_facet |
Mohamad Salim, Maheza Irna Tumiran, Mohammad Azizi Makhtar, Siti Noormiza Rosidi, Bustanur Ariffin, Ismail Ahmad, Abdul Hamid Supriyanto, Eko |
author_sort |
Mohamad Salim, Maheza Irna |
title |
Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis |
title_short |
Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis |
title_full |
Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis |
title_fullStr |
Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis |
title_full_unstemmed |
Hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis |
title_sort |
hybrid magnetoacoustic method for breast tumor detection: an in-vivo and in-vitro modelling and analysis |
publisher |
World Scientific and Engineering Academy and Society |
publishDate |
2010 |
url |
http://eprints.utm.my/id/eprint/25904/ https://www.researchgate.net/publication/234803238_Hybrid_magnetoacoustic_method_for_breast_tumor_detection_An_in-vivo_and_in-vitro_modelling_and_analysis |
_version_ |
1643647621845221376 |
score |
13.211869 |