Determination of best location of UPFC device for damping oscillation

Unified Power Flow Controller (UPFC) is use for controlling the real and reactive power on the transmission line and the bus voltage simultaneously and independently. An additional task of UPFC is to increase transmission capacity as result of power oscillation damping. The effectiveness of this con...

Full description

Saved in:
Bibliographic Details
Main Authors: Magaji, Nuraddeen, Mustafa, Mohd. Wazir, Muda, Zaniah
Format: Article
Published: EuroJournals Publishing 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/25093/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.25093
record_format eprints
spelling my.utm.250932018-03-22T10:32:17Z http://eprints.utm.my/id/eprint/25093/ Determination of best location of UPFC device for damping oscillation Magaji, Nuraddeen Mustafa, Mohd. Wazir Muda, Zaniah TK Electrical engineering. Electronics Nuclear engineering Unified Power Flow Controller (UPFC) is use for controlling the real and reactive power on the transmission line and the bus voltage simultaneously and independently. An additional task of UPFC is to increase transmission capacity as result of power oscillation damping. The effectiveness of this controller depends on its optimal location in the power system network. A residue factor has been proposed to find the optimal location of the UPFC controllers and Eigen value analyses are used to assess the most appropriate input signals (stabilizing signal) for supplementary damping control of UPFC to damp out the inter-area mode of oscillations. The proposed residue factor is based on the relative participation of the parameters of UPFC controller to the critical mode. A simple approach of computing the residue factor has been proposed, which combines the linearized differential algebraic equation model of the power system and the UPFC output equations. The placements of UPFC controllers have been obtained for the base case and for the dynamic critical contingences. The effectiveness of the proposed method of placement is demonstrated on practical network of 25 bus south Malaysian Power system. EuroJournals Publishing 2010 Article PeerReviewed Magaji, Nuraddeen and Mustafa, Mohd. Wazir and Muda, Zaniah (2010) Determination of best location of UPFC device for damping oscillation. European Journal of Scientific Research, 41 (2). 203 - 211. ISSN 1450-216X
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Magaji, Nuraddeen
Mustafa, Mohd. Wazir
Muda, Zaniah
Determination of best location of UPFC device for damping oscillation
description Unified Power Flow Controller (UPFC) is use for controlling the real and reactive power on the transmission line and the bus voltage simultaneously and independently. An additional task of UPFC is to increase transmission capacity as result of power oscillation damping. The effectiveness of this controller depends on its optimal location in the power system network. A residue factor has been proposed to find the optimal location of the UPFC controllers and Eigen value analyses are used to assess the most appropriate input signals (stabilizing signal) for supplementary damping control of UPFC to damp out the inter-area mode of oscillations. The proposed residue factor is based on the relative participation of the parameters of UPFC controller to the critical mode. A simple approach of computing the residue factor has been proposed, which combines the linearized differential algebraic equation model of the power system and the UPFC output equations. The placements of UPFC controllers have been obtained for the base case and for the dynamic critical contingences. The effectiveness of the proposed method of placement is demonstrated on practical network of 25 bus south Malaysian Power system.
format Article
author Magaji, Nuraddeen
Mustafa, Mohd. Wazir
Muda, Zaniah
author_facet Magaji, Nuraddeen
Mustafa, Mohd. Wazir
Muda, Zaniah
author_sort Magaji, Nuraddeen
title Determination of best location of UPFC device for damping oscillation
title_short Determination of best location of UPFC device for damping oscillation
title_full Determination of best location of UPFC device for damping oscillation
title_fullStr Determination of best location of UPFC device for damping oscillation
title_full_unstemmed Determination of best location of UPFC device for damping oscillation
title_sort determination of best location of upfc device for damping oscillation
publisher EuroJournals Publishing
publishDate 2010
url http://eprints.utm.my/id/eprint/25093/
_version_ 1643647555715727360
score 13.160551