Broken insulator effects on charge distribution measurement along suspension insulators
In the early years of power system network, porcelain and glass were used and still continuously serve the overhead lines to the present time. Obviously, they can provide distinction services over a long period of time. In spite of that, one or two of the insulators in the suspension may be damaged...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Penerbit UTHM
2020
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/24695/ http://dx.doi.org/10.30880/ijie.2020.12.02.012 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.24695 |
---|---|
record_format |
eprints |
spelling |
my.utm.246952022-02-28T12:18:12Z http://eprints.utm.my/id/eprint/24695/ Broken insulator effects on charge distribution measurement along suspension insulators Rosli, H. Othman, N. A. Piah, M. A. M. Jamail, N. A. M. Yousof, N. F. M. Ismail, M. N. TK Electrical engineering. Electronics Nuclear engineering In the early years of power system network, porcelain and glass were used and still continuously serve the overhead lines to the present time. Obviously, they can provide distinction services over a long period of time. In spite of that, one or two of the insulators in the suspension may be damaged due to some cases yet the suspension insulator is believed can still be used for a certain amount of time. By studying some research from previous works, it is accepted that the different properties of porcelain and glass type had made these insulators vary in their respective capabilities to serve overhead lines. This paper endeavours the distribution of charge for the porcelain suspension insulator using chamber method. Finite element software particularly QuickfieldTM was used in simulation purpose to validate the experimental results. Similar patterns of charge distributions were acquired for both experimental and simulation works. Penerbit UTHM 2020 Article PeerReviewed Rosli, H. and Othman, N. A. and Piah, M. A. M. and Jamail, N. A. M. and Yousof, N. F. M. and Ismail, M. N. (2020) Broken insulator effects on charge distribution measurement along suspension insulators. International Journal of Integrated Engineering, 12 (2). pp. 97-105. ISSN 2229-838X http://dx.doi.org/10.30880/ijie.2020.12.02.012 DOI: 10.30880/ijie.2020.12.02.012 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Rosli, H. Othman, N. A. Piah, M. A. M. Jamail, N. A. M. Yousof, N. F. M. Ismail, M. N. Broken insulator effects on charge distribution measurement along suspension insulators |
description |
In the early years of power system network, porcelain and glass were used and still continuously serve the overhead lines to the present time. Obviously, they can provide distinction services over a long period of time. In spite of that, one or two of the insulators in the suspension may be damaged due to some cases yet the suspension insulator is believed can still be used for a certain amount of time. By studying some research from previous works, it is accepted that the different properties of porcelain and glass type had made these insulators vary in their respective capabilities to serve overhead lines. This paper endeavours the distribution of charge for the porcelain suspension insulator using chamber method. Finite element software particularly QuickfieldTM was used in simulation purpose to validate the experimental results. Similar patterns of charge distributions were acquired for both experimental and simulation works. |
format |
Article |
author |
Rosli, H. Othman, N. A. Piah, M. A. M. Jamail, N. A. M. Yousof, N. F. M. Ismail, M. N. |
author_facet |
Rosli, H. Othman, N. A. Piah, M. A. M. Jamail, N. A. M. Yousof, N. F. M. Ismail, M. N. |
author_sort |
Rosli, H. |
title |
Broken insulator effects on charge distribution measurement along suspension insulators |
title_short |
Broken insulator effects on charge distribution measurement along suspension insulators |
title_full |
Broken insulator effects on charge distribution measurement along suspension insulators |
title_fullStr |
Broken insulator effects on charge distribution measurement along suspension insulators |
title_full_unstemmed |
Broken insulator effects on charge distribution measurement along suspension insulators |
title_sort |
broken insulator effects on charge distribution measurement along suspension insulators |
publisher |
Penerbit UTHM |
publishDate |
2020 |
url |
http://eprints.utm.my/id/eprint/24695/ http://dx.doi.org/10.30880/ijie.2020.12.02.012 |
_version_ |
1726791438937620480 |
score |
13.209306 |