Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram

This paper presents the hardware design of 2- channel data acquisition system for heart sound and Electrocardiogram (ECG) to capture the heart sound and ECG simultaneously from patients; and software algorithm to detect the first heart sound (S1) and second heart sound(S2). The algorithm utilizes In...

Full description

Saved in:
Bibliographic Details
Main Authors: Malarvili, M. B., J., M. Najeb, Ismail, Kamarulafizam
Format: Conference or Workshop Item
Language:English
Published: 2003
Subjects:
Online Access:http://eprints.utm.my/id/eprint/2152/1/malar2003__comet.pdf
http://eprints.utm.my/id/eprint/2152/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.2152
record_format eprints
spelling my.utm.21522011-06-06T08:09:31Z http://eprints.utm.my/id/eprint/2152/ Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram Malarvili, M. B. J., M. Najeb Ismail, Kamarulafizam TK Electrical engineering. Electronics Nuclear engineering This paper presents the hardware design of 2- channel data acquisition system for heart sound and Electrocardiogram (ECG) to capture the heart sound and ECG simultaneously from patients; and software algorithm to detect the first heart sound (S1) and second heart sound(S2). The algorithm utilizes Instantaneous Energy of ECG to estimate the presence of S1 and S2. Thus, heart sound segmentation can be done as it is essential in the automatic diagnosis of heart sounds. The Instantaneous Energy of ECG is performed to verify the occurrence of S1 and S2 as it is widely accepted pathologically that Phonocardiogram (PCG) and Electrocardiogram (ECG) are two noninvasive source of information depicting the cardiac activity [6]. The hardware consists of instrumentation amplifier, filter, isolation amplifier for each channel, multiplexer, Analogue to Digital Converter (ADC) and microcontroller 68HC11 to control and handle communication protocols with PC. The algorithm was tested for 210 cardiac cycles of heart sound and ECG recorded from patients from normal and abnormal simultaneously. 2003 Conference or Workshop Item NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/2152/1/malar2003__comet.pdf Malarvili, M. B. and J., M. Najeb and Ismail, Kamarulafizam (2003) Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram. In: COMET2003, 13-14 December 2003, Universiti Teknologi Malaysia.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Malarvili, M. B.
J., M. Najeb
Ismail, Kamarulafizam
Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram
description This paper presents the hardware design of 2- channel data acquisition system for heart sound and Electrocardiogram (ECG) to capture the heart sound and ECG simultaneously from patients; and software algorithm to detect the first heart sound (S1) and second heart sound(S2). The algorithm utilizes Instantaneous Energy of ECG to estimate the presence of S1 and S2. Thus, heart sound segmentation can be done as it is essential in the automatic diagnosis of heart sounds. The Instantaneous Energy of ECG is performed to verify the occurrence of S1 and S2 as it is widely accepted pathologically that Phonocardiogram (PCG) and Electrocardiogram (ECG) are two noninvasive source of information depicting the cardiac activity [6]. The hardware consists of instrumentation amplifier, filter, isolation amplifier for each channel, multiplexer, Analogue to Digital Converter (ADC) and microcontroller 68HC11 to control and handle communication protocols with PC. The algorithm was tested for 210 cardiac cycles of heart sound and ECG recorded from patients from normal and abnormal simultaneously.
format Conference or Workshop Item
author Malarvili, M. B.
J., M. Najeb
Ismail, Kamarulafizam
author_facet Malarvili, M. B.
J., M. Najeb
Ismail, Kamarulafizam
author_sort Malarvili, M. B.
title Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram
title_short Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram
title_full Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram
title_fullStr Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram
title_full_unstemmed Two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram
title_sort two channel data acquisition system for heart sound segmentation algorithm based on instantaneous energy of electrocardiogram
publishDate 2003
url http://eprints.utm.my/id/eprint/2152/1/malar2003__comet.pdf
http://eprints.utm.my/id/eprint/2152/
_version_ 1643643514328711168
score 13.18916