Transformer-isolated inverters are widely used in ac/dc power conversion that requires galvanic isolation between the source and load. The main applications for these inverters are the uninterruptible power supply, AC motor drives and renewable energy systems. Besides providing electrical isolati...

Full description

Saved in:
Bibliographic Details
Main Authors: Salam, Zainal, Ramli, Mohd. Zulkifli
Format: Book Section
Language:English
Published: Penerbit UTM 2008
Subjects:
Online Access:http://eprints.utm.my/id/eprint/16244/1/A_modified_DC-DC_type_high_frequency_transformer-link_inverter_incorporating_a_regenerative_snubber.pdf
http://eprints.utm.my/id/eprint/16244/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.16244
record_format eprints
spelling my.utm.162442011-10-21T09:40:24Z http://eprints.utm.my/id/eprint/16244/ A modified DC-DC type high frequency transformer-link inverter incorporating a regenerative snubber Salam, Zainal Ramli, Mohd. Zulkifli TK Electrical engineering. Electronics Nuclear engineering Transformer-isolated inverters are widely used in ac/dc power conversion that requires galvanic isolation between the source and load. The main applications for these inverters are the uninterruptible power supply, AC motor drives and renewable energy systems. Besides providing electrical isolation, the transformer is used to match the input-output voltage levels requirement. The conventional inverter normally utilises the line-frequency (50Hz) transformer. This circuit is very attractive because it requires minimum number of power switches and therefore exhibits low on-state conduction losses. Furthermore this inverter is inherently bidirectional, i.e. the power can flow from source to load and vice versa. This is mandatory for inverter with inductive loads, as during certain parts of the sinusoidal cycle, the current direction is reversed. The bidirectional capability is accomplished by the diodes which are placed in anti-parallel to the main power transistors. Despite its simplicity and inherent bidirectional capability, there remains one drawback of this topology, i.e. the 50Hz transformer. This component constitutes a significant portion of the inverter’s weight and space. An alternative to this topology is the high frequency (HF) transformer link inverter. This type of inverter is compact and lightweight due to the size of the ferrite transformer operated at high frequency. However, the overall inverter is significantly more complex in terms of circuit design and construction. Nevertheless, in applications where weight and size is the major limitation, this inverter can be a cost-effective choice. In a previous work, the dc-dc converter type bidirectional HF link inverter has been described [1]. One of the main concerns of this topology is the occurrence of large spike across the active rectifier’s switches. Its presence is caused by the leakage inductance at the transformer’s secondary. Although this is important, it was not adequately explained in [1] as the focus was on the topological and modulation aspect of the inverter. This work is intended to address the problem by proposing a modification to the inverter. The spike is suppressed by introducing a regenerative snubber network at the transformer’s secondary circuit. By employing the snubber, the voltage spike is effectively reduced to a very low value. In addition, the energy contained in the spike is converted back to the main power stage. This will further increase the efficiency of the inverter. Penerbit UTM 2008 Book Section PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/16244/1/A_modified_DC-DC_type_high_frequency_transformer-link_inverter_incorporating_a_regenerative_snubber.pdf Salam, Zainal and Ramli, Mohd. Zulkifli (2008) A modified DC-DC type high frequency transformer-link inverter incorporating a regenerative snubber. In: Recent Advances In Power Inverter. Penerbit UTM , Johor, pp. 17-28. ISBN 978-983-52-0647-4
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Salam, Zainal
Ramli, Mohd. Zulkifli
A modified DC-DC type high frequency transformer-link inverter incorporating a regenerative snubber
description Transformer-isolated inverters are widely used in ac/dc power conversion that requires galvanic isolation between the source and load. The main applications for these inverters are the uninterruptible power supply, AC motor drives and renewable energy systems. Besides providing electrical isolation, the transformer is used to match the input-output voltage levels requirement. The conventional inverter normally utilises the line-frequency (50Hz) transformer. This circuit is very attractive because it requires minimum number of power switches and therefore exhibits low on-state conduction losses. Furthermore this inverter is inherently bidirectional, i.e. the power can flow from source to load and vice versa. This is mandatory for inverter with inductive loads, as during certain parts of the sinusoidal cycle, the current direction is reversed. The bidirectional capability is accomplished by the diodes which are placed in anti-parallel to the main power transistors. Despite its simplicity and inherent bidirectional capability, there remains one drawback of this topology, i.e. the 50Hz transformer. This component constitutes a significant portion of the inverter’s weight and space. An alternative to this topology is the high frequency (HF) transformer link inverter. This type of inverter is compact and lightweight due to the size of the ferrite transformer operated at high frequency. However, the overall inverter is significantly more complex in terms of circuit design and construction. Nevertheless, in applications where weight and size is the major limitation, this inverter can be a cost-effective choice. In a previous work, the dc-dc converter type bidirectional HF link inverter has been described [1]. One of the main concerns of this topology is the occurrence of large spike across the active rectifier’s switches. Its presence is caused by the leakage inductance at the transformer’s secondary. Although this is important, it was not adequately explained in [1] as the focus was on the topological and modulation aspect of the inverter. This work is intended to address the problem by proposing a modification to the inverter. The spike is suppressed by introducing a regenerative snubber network at the transformer’s secondary circuit. By employing the snubber, the voltage spike is effectively reduced to a very low value. In addition, the energy contained in the spike is converted back to the main power stage. This will further increase the efficiency of the inverter.
format Book Section
author Salam, Zainal
Ramli, Mohd. Zulkifli
author_facet Salam, Zainal
Ramli, Mohd. Zulkifli
author_sort Salam, Zainal
title A modified DC-DC type high frequency transformer-link inverter incorporating a regenerative snubber
title_short A modified DC-DC type high frequency transformer-link inverter incorporating a regenerative snubber
title_full A modified DC-DC type high frequency transformer-link inverter incorporating a regenerative snubber
title_fullStr A modified DC-DC type high frequency transformer-link inverter incorporating a regenerative snubber
title_full_unstemmed A modified DC-DC type high frequency transformer-link inverter incorporating a regenerative snubber
title_sort modified dc-dc type high frequency transformer-link inverter incorporating a regenerative snubber
publisher Penerbit UTM
publishDate 2008
url http://eprints.utm.my/id/eprint/16244/1/A_modified_DC-DC_type_high_frequency_transformer-link_inverter_incorporating_a_regenerative_snubber.pdf
http://eprints.utm.my/id/eprint/16244/
_version_ 1643646504568619008
score 13.209306