The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia

This study investigates the effectiveness of night ventilation technique for residential buildings in hot-humid climate of Malaysia. This paper firstly presents the results of a survey on usage patterns of windows and air-conditioners in typical Malaysian residential areas. Secondly, the effects of...

Full description

Saved in:
Bibliographic Details
Main Authors: Kubota, Tetsu, Chyee, Doris Toe Hooi, Ahmad, Supian
Format: Article
Published: Elsevier BV 2009
Subjects:
Online Access:http://eprints.utm.my/id/eprint/13139/
http://dx.doi.org/10.1016/j.enbuild.2009.03.008
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.13139
record_format eprints
spelling my.utm.131392011-07-19T09:34:22Z http://eprints.utm.my/id/eprint/13139/ The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia Kubota, Tetsu Chyee, Doris Toe Hooi Ahmad, Supian NA Architecture This study investigates the effectiveness of night ventilation technique for residential buildings in hot-humid climate of Malaysia. This paper firstly presents the results of a survey on usage patterns of windows and air-conditioners in typical Malaysian residential areas. Secondly, the effects of different natural ventilation strategies on indoor thermal environment for Malaysian terraced houses are evaluated based on the results of a full-scale field experiment. The results show that the majority of occupants tend to apply not night ventilation but daytime ventilation in Malaysian residential areas. It can be seen from the field experiment that night ventilation would provide better thermal comfort for occupants in Malaysian terraced houses compared with the other ventilation strategies in terms of operative temperature. However, when the evaporative heat loss of occupants is taken into account by using SET*, the night ventilation would not be the superior technique to the others in providing daytime thermal comfort mainly due to the high humidity conditions. Therefore, the indoor humidity control during the daytime such as by dehumidification would be needed when the night ventilation technique is applied to Malaysian terraced houses. Otherwise, full-day ventilation would be a better option compared with night ventilation. Elsevier BV 2009-08 Article PeerReviewed Kubota, Tetsu and Chyee, Doris Toe Hooi and Ahmad, Supian (2009) The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia. Energy and Buildings, 41 (8). pp. 829-839. ISSN 0378-7788 http://dx.doi.org/10.1016/j.enbuild.2009.03.008 doi:10.1016/j.enbuild.2009.03.008
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic NA Architecture
spellingShingle NA Architecture
Kubota, Tetsu
Chyee, Doris Toe Hooi
Ahmad, Supian
The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia
description This study investigates the effectiveness of night ventilation technique for residential buildings in hot-humid climate of Malaysia. This paper firstly presents the results of a survey on usage patterns of windows and air-conditioners in typical Malaysian residential areas. Secondly, the effects of different natural ventilation strategies on indoor thermal environment for Malaysian terraced houses are evaluated based on the results of a full-scale field experiment. The results show that the majority of occupants tend to apply not night ventilation but daytime ventilation in Malaysian residential areas. It can be seen from the field experiment that night ventilation would provide better thermal comfort for occupants in Malaysian terraced houses compared with the other ventilation strategies in terms of operative temperature. However, when the evaporative heat loss of occupants is taken into account by using SET*, the night ventilation would not be the superior technique to the others in providing daytime thermal comfort mainly due to the high humidity conditions. Therefore, the indoor humidity control during the daytime such as by dehumidification would be needed when the night ventilation technique is applied to Malaysian terraced houses. Otherwise, full-day ventilation would be a better option compared with night ventilation.
format Article
author Kubota, Tetsu
Chyee, Doris Toe Hooi
Ahmad, Supian
author_facet Kubota, Tetsu
Chyee, Doris Toe Hooi
Ahmad, Supian
author_sort Kubota, Tetsu
title The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia
title_short The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia
title_full The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia
title_fullStr The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia
title_full_unstemmed The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia
title_sort effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of malaysia
publisher Elsevier BV
publishDate 2009
url http://eprints.utm.my/id/eprint/13139/
http://dx.doi.org/10.1016/j.enbuild.2009.03.008
_version_ 1643646126828552192
score 13.153044