Optimal sizing for a gas-fired grid-connected cogeneration system planning

This paper presents an optimization approach to determine the optimal sizing for a gas-fired grid-connected cogeneration system planning. An absorption chiller and a thermal storage system are included as part of the cogeneration system configuration. The optimization uses a mixed-integer nonlinear...

Full description

Saved in:
Bibliographic Details
Main Authors: Azit, Abu Hanifah, Mohamed Nor, Khalid
Format: Article
Published: Institute of Electrical and Electronics Engineers 2009
Subjects:
Online Access:http://eprints.utm.my/id/eprint/13032/
http://dx.doi.org/10.1109/TEC.2009.2026620
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.13032
record_format eprints
spelling my.utm.130322011-07-14T01:24:18Z http://eprints.utm.my/id/eprint/13032/ Optimal sizing for a gas-fired grid-connected cogeneration system planning Azit, Abu Hanifah Mohamed Nor, Khalid TK Electrical engineering. Electronics Nuclear engineering This paper presents an optimization approach to determine the optimal sizing for a gas-fired grid-connected cogeneration system planning. An absorption chiller and a thermal storage system are included as part of the cogeneration system configuration. The optimization uses a mixed-integer nonlinear optimization technique to size the system. The search for the minimum operational cost uses a NewtonRaphson and conjugate method with tangent estimates and forward derivatives. In certain cases, the approach uses dynamic programming principle to decide on the best feasible practical solution. The electrical and thermal outputs from the turbogenerator are modeled by taking into account partial loading. The annual facility load is represented by a week of hourly load. The optimization variables used are the one week of hourly electrical energy output from the turbogenerator and the optimum solution is determined by minimizing the total operational cost. The paper evaluates three case studies of different types of load characteristic (hospital, university campus, and paper mill) to demonstrate the capabilities of the proposed model. The optimum size of the whole system will be presented. The paper will also present the financial analysis of the optimum system. Institute of Electrical and Electronics Engineers 2009-12 Article PeerReviewed Azit, Abu Hanifah and Mohamed Nor, Khalid (2009) Optimal sizing for a gas-fired grid-connected cogeneration system planning. IEEE Transactions on Energy Conversion , 24 (4). 950 -958. ISSN 0885-8969 http://dx.doi.org/10.1109/TEC.2009.2026620 doi:10.1109/TEC.2009.2026620
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Azit, Abu Hanifah
Mohamed Nor, Khalid
Optimal sizing for a gas-fired grid-connected cogeneration system planning
description This paper presents an optimization approach to determine the optimal sizing for a gas-fired grid-connected cogeneration system planning. An absorption chiller and a thermal storage system are included as part of the cogeneration system configuration. The optimization uses a mixed-integer nonlinear optimization technique to size the system. The search for the minimum operational cost uses a NewtonRaphson and conjugate method with tangent estimates and forward derivatives. In certain cases, the approach uses dynamic programming principle to decide on the best feasible practical solution. The electrical and thermal outputs from the turbogenerator are modeled by taking into account partial loading. The annual facility load is represented by a week of hourly load. The optimization variables used are the one week of hourly electrical energy output from the turbogenerator and the optimum solution is determined by minimizing the total operational cost. The paper evaluates three case studies of different types of load characteristic (hospital, university campus, and paper mill) to demonstrate the capabilities of the proposed model. The optimum size of the whole system will be presented. The paper will also present the financial analysis of the optimum system.
format Article
author Azit, Abu Hanifah
Mohamed Nor, Khalid
author_facet Azit, Abu Hanifah
Mohamed Nor, Khalid
author_sort Azit, Abu Hanifah
title Optimal sizing for a gas-fired grid-connected cogeneration system planning
title_short Optimal sizing for a gas-fired grid-connected cogeneration system planning
title_full Optimal sizing for a gas-fired grid-connected cogeneration system planning
title_fullStr Optimal sizing for a gas-fired grid-connected cogeneration system planning
title_full_unstemmed Optimal sizing for a gas-fired grid-connected cogeneration system planning
title_sort optimal sizing for a gas-fired grid-connected cogeneration system planning
publisher Institute of Electrical and Electronics Engineers
publishDate 2009
url http://eprints.utm.my/id/eprint/13032/
http://dx.doi.org/10.1109/TEC.2009.2026620
_version_ 1643646099867566080
score 13.160551