Equine gait recognition using wearable technology for endurance monitoring: A preliminary study.

To overcome limitation in equine gait monitoring, a low-cost monitoring device is needed especially for long-distance event performance monitoring. Current devices capture horse gait in limited range of distance, limited duration usage and expensive. Mobile application such as Androsensor has shown...

Full description

Saved in:
Bibliographic Details
Main Authors: Yusoff, Nurshafitrah, Azaman, Aizreena
Format: Article
Language:English
Published: Penerbit UTM Press 2023
Subjects:
Online Access:http://eprints.utm.my/108615/1/NurshafitrahYusoff2023_EquineGaitRecognitionusingWearableTechnology.pdf
http://eprints.utm.my/108615/
http://dx.doi.org/10.11113/humentech.v2n1.44
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.108615
record_format eprints
spelling my.utm.1086152024-11-20T08:05:25Z http://eprints.utm.my/108615/ Equine gait recognition using wearable technology for endurance monitoring: A preliminary study. Yusoff, Nurshafitrah Azaman, Aizreena Q Science (General) To overcome limitation in equine gait monitoring, a low-cost monitoring device is needed especially for long-distance event performance monitoring. Current devices capture horse gait in limited range of distance, limited duration usage and expensive. Mobile application such as Androsensor has shown a great potential in horse gait recognition. However, further study is still warranted in order to determine the reliability of this kind of mobile application for performance monitoring especially for long-distance event such as endurance. In this study, a validation test of Androsensor mobile application for equine gait patterns recognition was conducted before the data can be applied for long-distance performance monitoring. Two horses (Thoroughbred) were used in this preliminary study. A unit of inertia measurement unit sensor (IMU) (Delsys Trigno Avanti Sensor) with 150 Hz sampling rate and a mini smartphone installed with Androsensor apps with 200 Hz sampling rate were attached together on horse forelimb pastern to compare the acceleration of horse gait signal captured by both devices. The data captured by both devices were analyzed. The correlation coefficient between an established device (IMU) and the Androsensor apps have shown a good correlation with higher correlation coefficient (r > 0.5) for walk, trot and canter. This finding indicates that the Androsensor mobile application has a great potential to be used in equine gait research and performance monitoring. It also can offer a wide function in this field as it is cheap and wearable. Penerbit UTM Press 2023-02-06 Article PeerReviewed application/pdf en http://eprints.utm.my/108615/1/NurshafitrahYusoff2023_EquineGaitRecognitionusingWearableTechnology.pdf Yusoff, Nurshafitrah and Azaman, Aizreena (2023) Equine gait recognition using wearable technology for endurance monitoring: A preliminary study. Journal of Human Centered Technology, 2 (1). pp. 61-67. ISSN 2821-3467 http://dx.doi.org/10.11113/humentech.v2n1.44 DOI:10.11113/humentech.v2n1.44
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic Q Science (General)
spellingShingle Q Science (General)
Yusoff, Nurshafitrah
Azaman, Aizreena
Equine gait recognition using wearable technology for endurance monitoring: A preliminary study.
description To overcome limitation in equine gait monitoring, a low-cost monitoring device is needed especially for long-distance event performance monitoring. Current devices capture horse gait in limited range of distance, limited duration usage and expensive. Mobile application such as Androsensor has shown a great potential in horse gait recognition. However, further study is still warranted in order to determine the reliability of this kind of mobile application for performance monitoring especially for long-distance event such as endurance. In this study, a validation test of Androsensor mobile application for equine gait patterns recognition was conducted before the data can be applied for long-distance performance monitoring. Two horses (Thoroughbred) were used in this preliminary study. A unit of inertia measurement unit sensor (IMU) (Delsys Trigno Avanti Sensor) with 150 Hz sampling rate and a mini smartphone installed with Androsensor apps with 200 Hz sampling rate were attached together on horse forelimb pastern to compare the acceleration of horse gait signal captured by both devices. The data captured by both devices were analyzed. The correlation coefficient between an established device (IMU) and the Androsensor apps have shown a good correlation with higher correlation coefficient (r > 0.5) for walk, trot and canter. This finding indicates that the Androsensor mobile application has a great potential to be used in equine gait research and performance monitoring. It also can offer a wide function in this field as it is cheap and wearable.
format Article
author Yusoff, Nurshafitrah
Azaman, Aizreena
author_facet Yusoff, Nurshafitrah
Azaman, Aizreena
author_sort Yusoff, Nurshafitrah
title Equine gait recognition using wearable technology for endurance monitoring: A preliminary study.
title_short Equine gait recognition using wearable technology for endurance monitoring: A preliminary study.
title_full Equine gait recognition using wearable technology for endurance monitoring: A preliminary study.
title_fullStr Equine gait recognition using wearable technology for endurance monitoring: A preliminary study.
title_full_unstemmed Equine gait recognition using wearable technology for endurance monitoring: A preliminary study.
title_sort equine gait recognition using wearable technology for endurance monitoring: a preliminary study.
publisher Penerbit UTM Press
publishDate 2023
url http://eprints.utm.my/108615/1/NurshafitrahYusoff2023_EquineGaitRecognitionusingWearableTechnology.pdf
http://eprints.utm.my/108615/
http://dx.doi.org/10.11113/humentech.v2n1.44
_version_ 1817841620678082560
score 13.223943