Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review

This paper collects, summarizes, and discusses more than a hundred important works on various causes, approaches, and advances in the supervision and diagnosis of extruded power cables, particularly the diagnosis of partial discharge (PD) in XLPE cables. This review focuses on four aspects of resear...

Full description

Saved in:
Bibliographic Details
Main Authors: Miftahul Fikri, Miftahul Fikri, Abdul-Malek, Zulkurnain
Format: Article
Published: Springer Science and Business Media Deutschland GmbH 2023
Subjects:
Online Access:http://eprints.utm.my/106598/
http://dx.doi.org/10.1007/s00202-023-01935-y
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.106598
record_format eprints
spelling my.utm.1065982024-07-09T07:59:02Z http://eprints.utm.my/106598/ Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review Miftahul Fikri, Miftahul Fikri Abdul-Malek, Zulkurnain TK Electrical engineering. Electronics Nuclear engineering This paper collects, summarizes, and discusses more than a hundred important works on various causes, approaches, and advances in the supervision and diagnosis of extruded power cables, particularly the diagnosis of partial discharge (PD) in XLPE cables. This review focuses on four aspects of research on the diagnosis of PD, namely the factors that affect PD in XLPE cables, comprehensive PD diagnosis under DC voltage, techniques for developing PD diagnosis, and lifetime analyses of XLPE cables. Several reviews on the diagnosis of PD in extruded power cables have been previously presented and analyzed. Nevertheless, most of the reviews tend to focus on the factors causing PD, and some discuss the diagnostic technique of PD in XLPE cable under AC voltage, while others do not provide a comprehensive review. In contrast with the previously published reviews, this paper highlights the factors that cause PD, PD diagnosis, and the remaining useful lifetime of XLPE cable under DC voltage. This review also provides the current position and development of PD diagnosis and lifetime XLPE cable under DC voltage, which can be a reference for further research for researchers regarding the actual impact of the topic in the field. Springer Science and Business Media Deutschland GmbH 2023 Article PeerReviewed Miftahul Fikri, Miftahul Fikri and Abdul-Malek, Zulkurnain (2023) Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review. Electrical Engineering, 105 (6). pp. 4195-4212. ISSN 0948-7921 http://dx.doi.org/10.1007/s00202-023-01935-y DOI : 10.1007/s00202-023-01935-y
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Miftahul Fikri, Miftahul Fikri
Abdul-Malek, Zulkurnain
Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review
description This paper collects, summarizes, and discusses more than a hundred important works on various causes, approaches, and advances in the supervision and diagnosis of extruded power cables, particularly the diagnosis of partial discharge (PD) in XLPE cables. This review focuses on four aspects of research on the diagnosis of PD, namely the factors that affect PD in XLPE cables, comprehensive PD diagnosis under DC voltage, techniques for developing PD diagnosis, and lifetime analyses of XLPE cables. Several reviews on the diagnosis of PD in extruded power cables have been previously presented and analyzed. Nevertheless, most of the reviews tend to focus on the factors causing PD, and some discuss the diagnostic technique of PD in XLPE cable under AC voltage, while others do not provide a comprehensive review. In contrast with the previously published reviews, this paper highlights the factors that cause PD, PD diagnosis, and the remaining useful lifetime of XLPE cable under DC voltage. This review also provides the current position and development of PD diagnosis and lifetime XLPE cable under DC voltage, which can be a reference for further research for researchers regarding the actual impact of the topic in the field.
format Article
author Miftahul Fikri, Miftahul Fikri
Abdul-Malek, Zulkurnain
author_facet Miftahul Fikri, Miftahul Fikri
Abdul-Malek, Zulkurnain
author_sort Miftahul Fikri, Miftahul Fikri
title Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review
title_short Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review
title_full Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review
title_fullStr Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review
title_full_unstemmed Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review
title_sort partial discharge diagnosis and remaining useful lifetime in xlpe extruded power cables under dc voltage: a review
publisher Springer Science and Business Media Deutschland GmbH
publishDate 2023
url http://eprints.utm.my/106598/
http://dx.doi.org/10.1007/s00202-023-01935-y
_version_ 1805880837387845632
score 13.18916