Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review
This paper collects, summarizes, and discusses more than a hundred important works on various causes, approaches, and advances in the supervision and diagnosis of extruded power cables, particularly the diagnosis of partial discharge (PD) in XLPE cables. This review focuses on four aspects of resear...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Published: |
Springer Science and Business Media Deutschland GmbH
2023
|
Subjects: | |
Online Access: | http://eprints.utm.my/106598/ http://dx.doi.org/10.1007/s00202-023-01935-y |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.106598 |
---|---|
record_format |
eprints |
spelling |
my.utm.1065982024-07-09T07:59:02Z http://eprints.utm.my/106598/ Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review Miftahul Fikri, Miftahul Fikri Abdul-Malek, Zulkurnain TK Electrical engineering. Electronics Nuclear engineering This paper collects, summarizes, and discusses more than a hundred important works on various causes, approaches, and advances in the supervision and diagnosis of extruded power cables, particularly the diagnosis of partial discharge (PD) in XLPE cables. This review focuses on four aspects of research on the diagnosis of PD, namely the factors that affect PD in XLPE cables, comprehensive PD diagnosis under DC voltage, techniques for developing PD diagnosis, and lifetime analyses of XLPE cables. Several reviews on the diagnosis of PD in extruded power cables have been previously presented and analyzed. Nevertheless, most of the reviews tend to focus on the factors causing PD, and some discuss the diagnostic technique of PD in XLPE cable under AC voltage, while others do not provide a comprehensive review. In contrast with the previously published reviews, this paper highlights the factors that cause PD, PD diagnosis, and the remaining useful lifetime of XLPE cable under DC voltage. This review also provides the current position and development of PD diagnosis and lifetime XLPE cable under DC voltage, which can be a reference for further research for researchers regarding the actual impact of the topic in the field. Springer Science and Business Media Deutschland GmbH 2023 Article PeerReviewed Miftahul Fikri, Miftahul Fikri and Abdul-Malek, Zulkurnain (2023) Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review. Electrical Engineering, 105 (6). pp. 4195-4212. ISSN 0948-7921 http://dx.doi.org/10.1007/s00202-023-01935-y DOI : 10.1007/s00202-023-01935-y |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Miftahul Fikri, Miftahul Fikri Abdul-Malek, Zulkurnain Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review |
description |
This paper collects, summarizes, and discusses more than a hundred important works on various causes, approaches, and advances in the supervision and diagnosis of extruded power cables, particularly the diagnosis of partial discharge (PD) in XLPE cables. This review focuses on four aspects of research on the diagnosis of PD, namely the factors that affect PD in XLPE cables, comprehensive PD diagnosis under DC voltage, techniques for developing PD diagnosis, and lifetime analyses of XLPE cables. Several reviews on the diagnosis of PD in extruded power cables have been previously presented and analyzed. Nevertheless, most of the reviews tend to focus on the factors causing PD, and some discuss the diagnostic technique of PD in XLPE cable under AC voltage, while others do not provide a comprehensive review. In contrast with the previously published reviews, this paper highlights the factors that cause PD, PD diagnosis, and the remaining useful lifetime of XLPE cable under DC voltage. This review also provides the current position and development of PD diagnosis and lifetime XLPE cable under DC voltage, which can be a reference for further research for researchers regarding the actual impact of the topic in the field. |
format |
Article |
author |
Miftahul Fikri, Miftahul Fikri Abdul-Malek, Zulkurnain |
author_facet |
Miftahul Fikri, Miftahul Fikri Abdul-Malek, Zulkurnain |
author_sort |
Miftahul Fikri, Miftahul Fikri |
title |
Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review |
title_short |
Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review |
title_full |
Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review |
title_fullStr |
Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review |
title_full_unstemmed |
Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review |
title_sort |
partial discharge diagnosis and remaining useful lifetime in xlpe extruded power cables under dc voltage: a review |
publisher |
Springer Science and Business Media Deutschland GmbH |
publishDate |
2023 |
url |
http://eprints.utm.my/106598/ http://dx.doi.org/10.1007/s00202-023-01935-y |
_version_ |
1805880837387845632 |
score |
13.18916 |