Doped plastic scintillator properties for soft tissue dosimetry

In medical dosimetry, the radiation quantity of interest is frequently the dose to tissue. To make direct dosimeters that show the dose absorbed in soft tissue, tissue-equivalent material is preferred. Plastic scintillators (PLS) are made of materials with a density similar to soft tissue and relati...

Full description

Saved in:
Bibliographic Details
Main Authors: Tajudin, S. M., Namito, Y., Sanami, T., Hirayama, H., Hashim, S.
Format: Article
Published: Institute of Electrical and Electronics Engineers Inc. 2022
Subjects:
Online Access:http://eprints.utm.my/104445/
http://dx.doi.org/10.1109/TNS.2022.3196353
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.104445
record_format eprints
spelling my.utm.1044452024-02-08T07:57:28Z http://eprints.utm.my/104445/ Doped plastic scintillator properties for soft tissue dosimetry Tajudin, S. M. Namito, Y. Sanami, T. Hirayama, H. Hashim, S. QC Physics In medical dosimetry, the radiation quantity of interest is frequently the dose to tissue. To make direct dosimeters that show the dose absorbed in soft tissue, tissue-equivalent material is preferred. Plastic scintillators (PLS) are made of materials with a density similar to soft tissue and relatively have energy independent response. Non-proportionality must be taken into account when reproducing the light output spectrum for photons below 200 keV, as it reduces light output significantly. In comparison to a standard plastic scintillator, both low and high energy photons’ pulse height distribution spectra as a result of lead doping were measured and calculated. The effect of a 0.5 % lead doping scintillator is sufficient to make up for the loss or difference between soft tissues and plastic scintillators in response to low energy photons, particularly below 200 keV. Institute of Electrical and Electronics Engineers Inc. 2022 Article PeerReviewed Tajudin, S. M. and Namito, Y. and Sanami, T. and Hirayama, H. and Hashim, S. (2022) Doped plastic scintillator properties for soft tissue dosimetry. IEEE Transactions on Nuclear Science, 69 (9). pp. 2108-2112. ISSN 0018-9499 http://dx.doi.org/10.1109/TNS.2022.3196353 DOI : 10.1109/TNS.2022.3196353
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QC Physics
spellingShingle QC Physics
Tajudin, S. M.
Namito, Y.
Sanami, T.
Hirayama, H.
Hashim, S.
Doped plastic scintillator properties for soft tissue dosimetry
description In medical dosimetry, the radiation quantity of interest is frequently the dose to tissue. To make direct dosimeters that show the dose absorbed in soft tissue, tissue-equivalent material is preferred. Plastic scintillators (PLS) are made of materials with a density similar to soft tissue and relatively have energy independent response. Non-proportionality must be taken into account when reproducing the light output spectrum for photons below 200 keV, as it reduces light output significantly. In comparison to a standard plastic scintillator, both low and high energy photons’ pulse height distribution spectra as a result of lead doping were measured and calculated. The effect of a 0.5 % lead doping scintillator is sufficient to make up for the loss or difference between soft tissues and plastic scintillators in response to low energy photons, particularly below 200 keV.
format Article
author Tajudin, S. M.
Namito, Y.
Sanami, T.
Hirayama, H.
Hashim, S.
author_facet Tajudin, S. M.
Namito, Y.
Sanami, T.
Hirayama, H.
Hashim, S.
author_sort Tajudin, S. M.
title Doped plastic scintillator properties for soft tissue dosimetry
title_short Doped plastic scintillator properties for soft tissue dosimetry
title_full Doped plastic scintillator properties for soft tissue dosimetry
title_fullStr Doped plastic scintillator properties for soft tissue dosimetry
title_full_unstemmed Doped plastic scintillator properties for soft tissue dosimetry
title_sort doped plastic scintillator properties for soft tissue dosimetry
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2022
url http://eprints.utm.my/104445/
http://dx.doi.org/10.1109/TNS.2022.3196353
_version_ 1792147742513954816
score 13.160551