Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure
This study presents the usage of Braided Actuators with Nested Structures to improve the stroke characteristics of the McKibben actuators. Thin McKibben actuators can contract 23% of their original length when pressurized. Usage of braiding and nested structures to improve contraction ratio has prov...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2022
|
Subjects: | |
Online Access: | http://eprints.utm.my/104435/ http://dx.doi.org/10.1109/LRA.2022.3192168 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.104435 |
---|---|
record_format |
eprints |
spelling |
my.utm.1044352024-02-04T10:03:14Z http://eprints.utm.my/104435/ Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure Abdul Kadir, Muhammad Raihan Mohd. Faudzi, Ahmad Athif Abdul Rahman, Mohd. Azizi T Technology (General) This study presents the usage of Braided Actuators with Nested Structures to improve the stroke characteristics of the McKibben actuators. Thin McKibben actuators can contract 23% of their original length when pressurized. Usage of braiding and nested structures to improve contraction ratio has proven successful. In this study, we use a combined telescopic Nested Structure and Braided Actuators to increase the contraction ratio of the actuators. The Nested Braided Actuator (NBA) performance was compared to Single Actuator (SA), Braided Actuator (BA), and Nested Actuator (NA). The results at 350 kPa indicate that, NBA had the highest contraction ratio of 45.5%, followed by NA (39.38%), BA (29.57%), and SA (23.41%). At 350 kPa, the contraction force per actuator NBA was 36.29 N, NA exerted 41.33 N, BA exerted 30.41 N and SA exerted 43.8 N. The actuator's performance showed that it was capable of high stroke with only a 20-30% loss in contraction force compared to the SA. Institute of Electrical and Electronics Engineers Inc. 2022 Article PeerReviewed Abdul Kadir, Muhammad Raihan and Mohd. Faudzi, Ahmad Athif and Abdul Rahman, Mohd. Azizi (2022) Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure. IEEE Robotics and Automation Letters, 7 (4). pp. 10906-10913. ISSN 2377-3766 http://dx.doi.org/10.1109/LRA.2022.3192168 DOI : 10.1109/LRA.2022.3192168 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Abdul Kadir, Muhammad Raihan Mohd. Faudzi, Ahmad Athif Abdul Rahman, Mohd. Azizi Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure |
description |
This study presents the usage of Braided Actuators with Nested Structures to improve the stroke characteristics of the McKibben actuators. Thin McKibben actuators can contract 23% of their original length when pressurized. Usage of braiding and nested structures to improve contraction ratio has proven successful. In this study, we use a combined telescopic Nested Structure and Braided Actuators to increase the contraction ratio of the actuators. The Nested Braided Actuator (NBA) performance was compared to Single Actuator (SA), Braided Actuator (BA), and Nested Actuator (NA). The results at 350 kPa indicate that, NBA had the highest contraction ratio of 45.5%, followed by NA (39.38%), BA (29.57%), and SA (23.41%). At 350 kPa, the contraction force per actuator NBA was 36.29 N, NA exerted 41.33 N, BA exerted 30.41 N and SA exerted 43.8 N. The actuator's performance showed that it was capable of high stroke with only a 20-30% loss in contraction force compared to the SA. |
format |
Article |
author |
Abdul Kadir, Muhammad Raihan Mohd. Faudzi, Ahmad Athif Abdul Rahman, Mohd. Azizi |
author_facet |
Abdul Kadir, Muhammad Raihan Mohd. Faudzi, Ahmad Athif Abdul Rahman, Mohd. Azizi |
author_sort |
Abdul Kadir, Muhammad Raihan |
title |
Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure |
title_short |
Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure |
title_full |
Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure |
title_fullStr |
Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure |
title_full_unstemmed |
Performance evaluation for Braided McKibben pneumatic actuators in telescopic nested structure |
title_sort |
performance evaluation for braided mckibben pneumatic actuators in telescopic nested structure |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2022 |
url |
http://eprints.utm.my/104435/ http://dx.doi.org/10.1109/LRA.2022.3192168 |
_version_ |
1792147740540534784 |
score |
13.211869 |