A comprehensive review of the recent developments in wearable sweat-sensing devices

Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the mea...

Full description

Saved in:
Bibliographic Details
Main Authors: Ibrahim, Nur Fatin Adini, Sabani, Norhayati, Johari, Shazlina, Abd. Manaf, Asrulnizam, Abdul Wahab, Asnida, Zakaria, Zulkarnay, Mohd. Noor, Anas
Format: Article
Language:English
Published: MDPI 2022
Subjects:
Online Access:http://eprints.utm.my/104024/1/AsnidaAbdulWahab2022_AComprehensiveReviewoftheRecentDevelopments.pdf
http://eprints.utm.my/104024/
http://dx.doi.org/10.3390/s22197670
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.104024
record_format eprints
spelling my.utm.1040242024-01-14T00:43:57Z http://eprints.utm.my/104024/ A comprehensive review of the recent developments in wearable sweat-sensing devices Ibrahim, Nur Fatin Adini Sabani, Norhayati Johari, Shazlina Abd. Manaf, Asrulnizam Abdul Wahab, Asnida Zakaria, Zulkarnay Mohd. Noor, Anas Q Science (General) Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis. In addition, the paper also comprehensively presents various sweat biomarkers that have been explored by earlier works in order to broaden the use of non-invasive sweat samples in healthcare and related applications. This work also discusses the target analyte’s response mechanism for different sweat compositions, categories of sweat collection devices, and recent advances in SSDs regarding optimal design, functionality, and performance. MDPI 2022-10 Article PeerReviewed application/pdf en http://eprints.utm.my/104024/1/AsnidaAbdulWahab2022_AComprehensiveReviewoftheRecentDevelopments.pdf Ibrahim, Nur Fatin Adini and Sabani, Norhayati and Johari, Shazlina and Abd. Manaf, Asrulnizam and Abdul Wahab, Asnida and Zakaria, Zulkarnay and Mohd. Noor, Anas (2022) A comprehensive review of the recent developments in wearable sweat-sensing devices. Sensors, 22 (19). pp. 1-45. ISSN 1424-8220 http://dx.doi.org/10.3390/s22197670 DOI:10.3390/s22197670
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic Q Science (General)
spellingShingle Q Science (General)
Ibrahim, Nur Fatin Adini
Sabani, Norhayati
Johari, Shazlina
Abd. Manaf, Asrulnizam
Abdul Wahab, Asnida
Zakaria, Zulkarnay
Mohd. Noor, Anas
A comprehensive review of the recent developments in wearable sweat-sensing devices
description Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis. In addition, the paper also comprehensively presents various sweat biomarkers that have been explored by earlier works in order to broaden the use of non-invasive sweat samples in healthcare and related applications. This work also discusses the target analyte’s response mechanism for different sweat compositions, categories of sweat collection devices, and recent advances in SSDs regarding optimal design, functionality, and performance.
format Article
author Ibrahim, Nur Fatin Adini
Sabani, Norhayati
Johari, Shazlina
Abd. Manaf, Asrulnizam
Abdul Wahab, Asnida
Zakaria, Zulkarnay
Mohd. Noor, Anas
author_facet Ibrahim, Nur Fatin Adini
Sabani, Norhayati
Johari, Shazlina
Abd. Manaf, Asrulnizam
Abdul Wahab, Asnida
Zakaria, Zulkarnay
Mohd. Noor, Anas
author_sort Ibrahim, Nur Fatin Adini
title A comprehensive review of the recent developments in wearable sweat-sensing devices
title_short A comprehensive review of the recent developments in wearable sweat-sensing devices
title_full A comprehensive review of the recent developments in wearable sweat-sensing devices
title_fullStr A comprehensive review of the recent developments in wearable sweat-sensing devices
title_full_unstemmed A comprehensive review of the recent developments in wearable sweat-sensing devices
title_sort comprehensive review of the recent developments in wearable sweat-sensing devices
publisher MDPI
publishDate 2022
url http://eprints.utm.my/104024/1/AsnidaAbdulWahab2022_AComprehensiveReviewoftheRecentDevelopments.pdf
http://eprints.utm.my/104024/
http://dx.doi.org/10.3390/s22197670
_version_ 1789424367341404160
score 13.160551