Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix

Due to the widespread proliferation of distributed generation resources and the current market situation, ensuring the security and reliability of power grids against fault events has become a more challenging task. The aim of this paper is to compare different power flow techniques for power grid v...

Full description

Saved in:
Bibliographic Details
Main Authors: Mirsaeidi, Sohrab, Rahman, Mahmuda, He, Jinghan, Lu, Geye, Mat Said, Dalila, Konstantinou, Charalambos, Li, Meng, Muttaqi, Kashem M., Dong, Xinzhou
Format: Article
Published: Elsevier Ltd 2022
Subjects:
Online Access:http://eprints.utm.my/103540/
http://dx.doi.org/10.1016/j.epsr.2022.108652
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.103540
record_format eprints
spelling my.utm.1035402023-11-14T06:40:16Z http://eprints.utm.my/103540/ Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix Mirsaeidi, Sohrab Rahman, Mahmuda He, Jinghan Lu, Geye Mat Said, Dalila Konstantinou, Charalambos Li, Meng Muttaqi, Kashem M. Dong, Xinzhou TK Electrical engineering. Electronics Nuclear engineering Due to the widespread proliferation of distributed generation resources and the current market situation, ensuring the security and reliability of power grids against fault events has become a more challenging task. The aim of this paper is to compare different power flow techniques for power grid vulnerability assessment against symmetrical fault incidents using bus impedance matrix. In this study, first, the relationship of the post-fault voltage phasor at each bus with the pre-fault voltage phasors at that bus and the faulted bus, impedance matrix elements, and fault impedance is investigated through power system analysis under pre-fault and post-fault circumstances. Subsequently, the accuracy of different iterative and non-iterative power flow algorithms, i.e. Newton Raphson (NR), Fast Decoupled (FD), and Direct Current (DC) methods, for the power grid vulnerability assessment is compared. To achieve this, the fault analysis at each bus is performed commencing with a very large fault impedance and ending with the fault impedance at which one of the buses reaches the low voltage violation limit. Finally, to appraise the proposed strategy, several simulations have been undertaken on IEEE 14 bus system using MATLAB software. The simulation results indicate that the power grid vulnerability against symmetrical faults is highly influenced by the type of applied power flow technique. Elsevier Ltd 2022 Article PeerReviewed Mirsaeidi, Sohrab and Rahman, Mahmuda and He, Jinghan and Lu, Geye and Mat Said, Dalila and Konstantinou, Charalambos and Li, Meng and Muttaqi, Kashem M. and Dong, Xinzhou (2022) Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix. Electric Power Systems Research, 212 (NA). pp. 1-13. ISSN 0378-7796 http://dx.doi.org/10.1016/j.epsr.2022.108652 DOI : 10.1016/j.epsr.2022.108652
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Mirsaeidi, Sohrab
Rahman, Mahmuda
He, Jinghan
Lu, Geye
Mat Said, Dalila
Konstantinou, Charalambos
Li, Meng
Muttaqi, Kashem M.
Dong, Xinzhou
Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix
description Due to the widespread proliferation of distributed generation resources and the current market situation, ensuring the security and reliability of power grids against fault events has become a more challenging task. The aim of this paper is to compare different power flow techniques for power grid vulnerability assessment against symmetrical fault incidents using bus impedance matrix. In this study, first, the relationship of the post-fault voltage phasor at each bus with the pre-fault voltage phasors at that bus and the faulted bus, impedance matrix elements, and fault impedance is investigated through power system analysis under pre-fault and post-fault circumstances. Subsequently, the accuracy of different iterative and non-iterative power flow algorithms, i.e. Newton Raphson (NR), Fast Decoupled (FD), and Direct Current (DC) methods, for the power grid vulnerability assessment is compared. To achieve this, the fault analysis at each bus is performed commencing with a very large fault impedance and ending with the fault impedance at which one of the buses reaches the low voltage violation limit. Finally, to appraise the proposed strategy, several simulations have been undertaken on IEEE 14 bus system using MATLAB software. The simulation results indicate that the power grid vulnerability against symmetrical faults is highly influenced by the type of applied power flow technique.
format Article
author Mirsaeidi, Sohrab
Rahman, Mahmuda
He, Jinghan
Lu, Geye
Mat Said, Dalila
Konstantinou, Charalambos
Li, Meng
Muttaqi, Kashem M.
Dong, Xinzhou
author_facet Mirsaeidi, Sohrab
Rahman, Mahmuda
He, Jinghan
Lu, Geye
Mat Said, Dalila
Konstantinou, Charalambos
Li, Meng
Muttaqi, Kashem M.
Dong, Xinzhou
author_sort Mirsaeidi, Sohrab
title Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix
title_short Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix
title_full Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix
title_fullStr Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix
title_full_unstemmed Comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix
title_sort comparison of different power flow techniques for power grid vulnerability assessment against symmetrical faults using bus impedance matrix
publisher Elsevier Ltd
publishDate 2022
url http://eprints.utm.my/103540/
http://dx.doi.org/10.1016/j.epsr.2022.108652
_version_ 1783876379249475584
score 13.211869