Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy

Wireless capsule endoscopy is designed to monitor the physical data from inside human stomach and gastro intestine tract and transfer data to the receiver device. Normal mode helical antenna that has high efficiency at a small size is selected for WCE. To clarify the radio wave communication link bu...

Full description

Saved in:
Bibliographic Details
Main Authors: Zainudin, Norsiha, Abdul Latef, Tarik, Yamada, Yoshihide, Kamardin, Kamilia, Kumar Aridas, Narendra, Kamaruddin, Nur Amalina, Md. Jizat, Noorlindawaty
Format: Article
Published: Taylor and Francis Ltd. 2022
Subjects:
Online Access:http://eprints.utm.my/103097/
http://dx.doi.org/10.1080/09205071.2022.2104658
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.103097
record_format eprints
spelling my.utm.1030972023-10-12T09:28:39Z http://eprints.utm.my/103097/ Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy Zainudin, Norsiha Abdul Latef, Tarik Yamada, Yoshihide Kamardin, Kamilia Kumar Aridas, Narendra Kamaruddin, Nur Amalina Md. Jizat, Noorlindawaty TK Electrical engineering. Electronics Nuclear engineering Wireless capsule endoscopy is designed to monitor the physical data from inside human stomach and gastro intestine tract and transfer data to the receiver device. Normal mode helical antenna that has high efficiency at a small size is selected for WCE. To clarify the radio wave communication link budget in the dielectric environment is crucial. In this paper, NMHA for WCE system at 402 MHz along with a link budget analysis is presented. The transmitter uses NMHA embedded in a cylindrical phantom mimicking human stomach tissue, whereas the receiver uses another NMHA located outside the body. The NMHA dimension of height and diameter are 18 mm × 11 and 37 mm × 18 mm respectively. Through this study, a novel method of analytical equations for the radio wave communication link in human body are derived. From the good agreement between simulated and measured S21, the effectiveness of derived equations is ensured. Taylor and Francis Ltd. 2022 Article PeerReviewed Zainudin, Norsiha and Abdul Latef, Tarik and Yamada, Yoshihide and Kamardin, Kamilia and Kumar Aridas, Narendra and Kamaruddin, Nur Amalina and Md. Jizat, Noorlindawaty (2022) Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy. Journal of Electromagnetic Waves and Applications, 36 (18). pp. 2672-2696. ISSN 0920-5071 http://dx.doi.org/10.1080/09205071.2022.2104658 DOI: 10.1080/09205071.2022.2104658
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Zainudin, Norsiha
Abdul Latef, Tarik
Yamada, Yoshihide
Kamardin, Kamilia
Kumar Aridas, Narendra
Kamaruddin, Nur Amalina
Md. Jizat, Noorlindawaty
Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy
description Wireless capsule endoscopy is designed to monitor the physical data from inside human stomach and gastro intestine tract and transfer data to the receiver device. Normal mode helical antenna that has high efficiency at a small size is selected for WCE. To clarify the radio wave communication link budget in the dielectric environment is crucial. In this paper, NMHA for WCE system at 402 MHz along with a link budget analysis is presented. The transmitter uses NMHA embedded in a cylindrical phantom mimicking human stomach tissue, whereas the receiver uses another NMHA located outside the body. The NMHA dimension of height and diameter are 18 mm × 11 and 37 mm × 18 mm respectively. Through this study, a novel method of analytical equations for the radio wave communication link in human body are derived. From the good agreement between simulated and measured S21, the effectiveness of derived equations is ensured.
format Article
author Zainudin, Norsiha
Abdul Latef, Tarik
Yamada, Yoshihide
Kamardin, Kamilia
Kumar Aridas, Narendra
Kamaruddin, Nur Amalina
Md. Jizat, Noorlindawaty
author_facet Zainudin, Norsiha
Abdul Latef, Tarik
Yamada, Yoshihide
Kamardin, Kamilia
Kumar Aridas, Narendra
Kamaruddin, Nur Amalina
Md. Jizat, Noorlindawaty
author_sort Zainudin, Norsiha
title Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy
title_short Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy
title_full Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy
title_fullStr Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy
title_full_unstemmed Nearfield radio link of normal mode helical antenna for wireless capsule endoscopy
title_sort nearfield radio link of normal mode helical antenna for wireless capsule endoscopy
publisher Taylor and Francis Ltd.
publishDate 2022
url http://eprints.utm.my/103097/
http://dx.doi.org/10.1080/09205071.2022.2104658
_version_ 1781777644538298368
score 13.160551