Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger

The one-directional flow condition and the bi-directional flow condition are two flow conditions that can be found in many energy systems depending on the nature of the flow and the working mechanism of the system. This paper reports the differences in heat transfer performance for an in-line tube b...

Full description

Saved in:
Bibliographic Details
Main Authors: Hasbullah, Nurjannah, Mohd. Saat, Fatimah Al Zahrah, Shikh Anuar, Fadhilah, Sukri, Mohamad Firdaus, Akop, Mohd. Zaid, Abdul Manan, Zainuddin
Format: Article
Published: Semarak Ilmu Publishing 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/102809/
http://dx.doi.org/10.37934/arfmts.96.2.7487
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.102809
record_format eprints
spelling my.utm.1028092023-09-20T04:32:19Z http://eprints.utm.my/id/eprint/102809/ Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger Hasbullah, Nurjannah Mohd. Saat, Fatimah Al Zahrah Shikh Anuar, Fadhilah Sukri, Mohamad Firdaus Akop, Mohd. Zaid Abdul Manan, Zainuddin TP Chemical technology The one-directional flow condition and the bi-directional flow condition are two flow conditions that can be found in many energy systems depending on the nature of the flow and the working mechanism of the system. This paper reports the differences in heat transfer performance for an in-line tube banks heat exchanger that is placed in the one-directional and the bi-directional flow conditions. The experiments involve the use of a blower as a flow inducer for one-directional flow while a loudspeaker with a constant frequency of 14.2 Hz is used as a flow inducer for bi-directional flow condition. A quarter wavelength resonator with 4 mm wall thickness and a length of 6600 mm was used in the investigation. The results of velocity and temperature were recorded using a hotwire anemometer and a type-K thermocouple, respectively. Results show that the behaviour of velocity and temperature in one-directional and the bi-directional flow conditions over an in-line heated tube banks are different with a maximum difference of 52 % for velocity and 79 % for temperature. Semarak Ilmu Publishing 2022 Article PeerReviewed Hasbullah, Nurjannah and Mohd. Saat, Fatimah Al Zahrah and Shikh Anuar, Fadhilah and Sukri, Mohamad Firdaus and Akop, Mohd. Zaid and Abdul Manan, Zainuddin (2022) Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 96 (2). pp. 74-87. ISSN 2289-7879 http://dx.doi.org/10.37934/arfmts.96.2.7487 DOI: 10.37934/arfmts.96.2.7487
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Hasbullah, Nurjannah
Mohd. Saat, Fatimah Al Zahrah
Shikh Anuar, Fadhilah
Sukri, Mohamad Firdaus
Akop, Mohd. Zaid
Abdul Manan, Zainuddin
Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger
description The one-directional flow condition and the bi-directional flow condition are two flow conditions that can be found in many energy systems depending on the nature of the flow and the working mechanism of the system. This paper reports the differences in heat transfer performance for an in-line tube banks heat exchanger that is placed in the one-directional and the bi-directional flow conditions. The experiments involve the use of a blower as a flow inducer for one-directional flow while a loudspeaker with a constant frequency of 14.2 Hz is used as a flow inducer for bi-directional flow condition. A quarter wavelength resonator with 4 mm wall thickness and a length of 6600 mm was used in the investigation. The results of velocity and temperature were recorded using a hotwire anemometer and a type-K thermocouple, respectively. Results show that the behaviour of velocity and temperature in one-directional and the bi-directional flow conditions over an in-line heated tube banks are different with a maximum difference of 52 % for velocity and 79 % for temperature.
format Article
author Hasbullah, Nurjannah
Mohd. Saat, Fatimah Al Zahrah
Shikh Anuar, Fadhilah
Sukri, Mohamad Firdaus
Akop, Mohd. Zaid
Abdul Manan, Zainuddin
author_facet Hasbullah, Nurjannah
Mohd. Saat, Fatimah Al Zahrah
Shikh Anuar, Fadhilah
Sukri, Mohamad Firdaus
Akop, Mohd. Zaid
Abdul Manan, Zainuddin
author_sort Hasbullah, Nurjannah
title Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger
title_short Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger
title_full Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger
title_fullStr Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger
title_full_unstemmed Experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger
title_sort experimental study on the performance of one-directional and bi-directional flow conditions across in-line tube banks heat exchanger
publisher Semarak Ilmu Publishing
publishDate 2022
url http://eprints.utm.my/id/eprint/102809/
http://dx.doi.org/10.37934/arfmts.96.2.7487
_version_ 1778160785131831296
score 13.160551