Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin

Sample preparation for the analysis of biological fluid samples posed significant challenges to the clinical laboratory. The current sample preparation practice involves multi-steps procedure that are time consuming and may lead to analytes lost. In this study, a low-cost, single-use sampling probe...

Full description

Saved in:
Bibliographic Details
Main Author: Tey, Hui Yin
Format: Thesis
Language:English
Published: 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/101505/1/TeyHuiYinPFS2022.pdf
http://eprints.utm.my/id/eprint/101505/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:149192
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.101505
record_format eprints
spelling my.utm.1015052023-06-23T02:52:04Z http://eprints.utm.my/id/eprint/101505/ Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin Tey, Hui Yin QD Chemistry Sample preparation for the analysis of biological fluid samples posed significant challenges to the clinical laboratory. The current sample preparation practice involves multi-steps procedure that are time consuming and may lead to analytes lost. In this study, a low-cost, single-use sampling probe was introduced for electric field driven extraction. The sampling probe consists of a non-conductive glass capillary substrate, and a polymer inclusion membrane (PIM) dip-coated on the glass capillary substrate. The probe features a user-friendly design that can electrically extract targeted analytes from biological fluid sample. The glass capillary, closed at one end, was dipped in a homogeneous membrane solution that consists of an optimum composition of cellulose triacetate (CTA), 2-nitrophenyl octyl ether (2-NPOE) and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMIM][NTf2]), yielded a PIM with thickness of 30 μm on the sampling probe. The effects of dipping cycles (thickness), voltage applied, and sample pH on the extraction efficiency of the sampling probe were thoroughly investigated. The concept of electrokinetic extraction using the PIM sampling probe was first demonstrated on the cationic model analyte, Rhodamine 6G at 500 V for 60 mins. The proven concept was then successfully applied to the extraction of the anticancer drug doxorubicin from samples in liquid or dried form, including dried blood spot (DBS), human plasma and human serum samples. The practicability and reliability of the electrokinetic extraction process were evaluated using liquid chromatography with tandem mass spectrometry (LC-MS/MS) to quantify the desorption of extracted doxorubicin from the PIM sampling probe. Under optimised conditions, the new method provided good linearity over a concentration range of 0.2 to 20 ng/mL; additionally, quantification limits of 0.2 to 2 ng/mL were achieved for the three biological samples and the relative recoveries ranged from 82.7 to 113.8% for DBS, human plasma and human serum samples; good method reproducibility was also achieved, with relative standard deviations (RSDs) ranging from 0.9 and 4.6%. The PIM sampling probe was further integrated into a portable battery-device for safe, lower-voltage (36 V) electrokinetic extraction. The correlation coefficients, r, for the two pairs of data were determined using the laboratory setup and the battery-powered device; values in the range of 0.9926 to 0.9996 were found, indicating an acceptable agreement. This new electrokinetic extraction approach represents a new opportunity for processing samples during sampling and transportation, saving time and reducing manual handling to produce more reliable test results efficiently. 2022 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/101505/1/TeyHuiYinPFS2022.pdf Tey, Hui Yin (2022) Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin. PhD thesis, Universiti Teknologi Malaysia, Faculty of Science. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:149192
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic QD Chemistry
spellingShingle QD Chemistry
Tey, Hui Yin
Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin
description Sample preparation for the analysis of biological fluid samples posed significant challenges to the clinical laboratory. The current sample preparation practice involves multi-steps procedure that are time consuming and may lead to analytes lost. In this study, a low-cost, single-use sampling probe was introduced for electric field driven extraction. The sampling probe consists of a non-conductive glass capillary substrate, and a polymer inclusion membrane (PIM) dip-coated on the glass capillary substrate. The probe features a user-friendly design that can electrically extract targeted analytes from biological fluid sample. The glass capillary, closed at one end, was dipped in a homogeneous membrane solution that consists of an optimum composition of cellulose triacetate (CTA), 2-nitrophenyl octyl ether (2-NPOE) and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMIM][NTf2]), yielded a PIM with thickness of 30 μm on the sampling probe. The effects of dipping cycles (thickness), voltage applied, and sample pH on the extraction efficiency of the sampling probe were thoroughly investigated. The concept of electrokinetic extraction using the PIM sampling probe was first demonstrated on the cationic model analyte, Rhodamine 6G at 500 V for 60 mins. The proven concept was then successfully applied to the extraction of the anticancer drug doxorubicin from samples in liquid or dried form, including dried blood spot (DBS), human plasma and human serum samples. The practicability and reliability of the electrokinetic extraction process were evaluated using liquid chromatography with tandem mass spectrometry (LC-MS/MS) to quantify the desorption of extracted doxorubicin from the PIM sampling probe. Under optimised conditions, the new method provided good linearity over a concentration range of 0.2 to 20 ng/mL; additionally, quantification limits of 0.2 to 2 ng/mL were achieved for the three biological samples and the relative recoveries ranged from 82.7 to 113.8% for DBS, human plasma and human serum samples; good method reproducibility was also achieved, with relative standard deviations (RSDs) ranging from 0.9 and 4.6%. The PIM sampling probe was further integrated into a portable battery-device for safe, lower-voltage (36 V) electrokinetic extraction. The correlation coefficients, r, for the two pairs of data were determined using the laboratory setup and the battery-powered device; values in the range of 0.9926 to 0.9996 were found, indicating an acceptable agreement. This new electrokinetic extraction approach represents a new opportunity for processing samples during sampling and transportation, saving time and reducing manual handling to produce more reliable test results efficiently.
format Thesis
author Tey, Hui Yin
author_facet Tey, Hui Yin
author_sort Tey, Hui Yin
title Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin
title_short Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin
title_full Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin
title_fullStr Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin
title_full_unstemmed Polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin
title_sort polymer inclusion membrane sampling probe for electric field driven extraction of doxorubicin
publishDate 2022
url http://eprints.utm.my/id/eprint/101505/1/TeyHuiYinPFS2022.pdf
http://eprints.utm.my/id/eprint/101505/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:149192
_version_ 1769842065024221184
score 13.251813