Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement

Electrical capacitance tomography (ECT) is a non-invasive imaging technique and has potential usage in lab-on-chip (LOC) imaging. The current design of on-chip ECT is reported to utilise the peripheral electrode arrangement where the planar electrodes are arranged at the side of sensing chamber. The...

Full description

Saved in:
Bibliographic Details
Main Authors: Gooi, Wen Pin, Leow, Pei Ling, Hor, Xian Feng, Mohammad Din, Shahrulnizahani
Format: Book Section
Published: Springer Science and Business Media Deutschland GmbH 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/100756/
http://dx.doi.org/10.1007/978-981-19-3923-5_64
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.100756
record_format eprints
spelling my.utm.1007562023-05-18T03:37:50Z http://eprints.utm.my/id/eprint/100756/ Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement Gooi, Wen Pin Leow, Pei Ling Hor, Xian Feng Mohammad Din, Shahrulnizahani TK Electrical engineering. Electronics Nuclear engineering Electrical capacitance tomography (ECT) is a non-invasive imaging technique and has potential usage in lab-on-chip (LOC) imaging. The current design of on-chip ECT is reported to utilise the peripheral electrode arrangement where the planar electrodes are arranged at the side of sensing chamber. The on-chip ECT using peripheral electrode arrangement is capable of 2D imaging but little is known on the practical application of the sensor design in 3D imaging as compared to the distributed electrode arrangement sensor. In this paper, the 3D imaging performance of peripheral and distributed electrode arrangement sensors was compared through a simulation study. A cube phantom was used as a test sample for 3D imaging and it was placed at several test positions in the sensing chamber. The 3D image was reconstructed by using the linear back projection (LBP) algorithm. The reconstructed 3D image was quantitatively analysed using the correlation coefficient and the spatial image error. Both electrode arrangement is able to reconstruct 3D images and distributed electrode arrangement sensor performed better than the peripheral. Springer Science and Business Media Deutschland GmbH 2022 Book Section PeerReviewed Gooi, Wen Pin and Leow, Pei Ling and Hor, Xian Feng and Mohammad Din, Shahrulnizahani (2022) Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement. In: Control, Instrumentation and Mechatronics: Theory and Practice. Lecture Notes in Electrical Engineering, 921 (NA). Springer Science and Business Media Deutschland GmbH, Singapore, pp. 741-751. ISBN 978-981193922-8 http://dx.doi.org/10.1007/978-981-19-3923-5_64 DOI:10.1007/978-981-19-3923-5_64
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Gooi, Wen Pin
Leow, Pei Ling
Hor, Xian Feng
Mohammad Din, Shahrulnizahani
Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement
description Electrical capacitance tomography (ECT) is a non-invasive imaging technique and has potential usage in lab-on-chip (LOC) imaging. The current design of on-chip ECT is reported to utilise the peripheral electrode arrangement where the planar electrodes are arranged at the side of sensing chamber. The on-chip ECT using peripheral electrode arrangement is capable of 2D imaging but little is known on the practical application of the sensor design in 3D imaging as compared to the distributed electrode arrangement sensor. In this paper, the 3D imaging performance of peripheral and distributed electrode arrangement sensors was compared through a simulation study. A cube phantom was used as a test sample for 3D imaging and it was placed at several test positions in the sensing chamber. The 3D image was reconstructed by using the linear back projection (LBP) algorithm. The reconstructed 3D image was quantitatively analysed using the correlation coefficient and the spatial image error. Both electrode arrangement is able to reconstruct 3D images and distributed electrode arrangement sensor performed better than the peripheral.
format Book Section
author Gooi, Wen Pin
Leow, Pei Ling
Hor, Xian Feng
Mohammad Din, Shahrulnizahani
author_facet Gooi, Wen Pin
Leow, Pei Ling
Hor, Xian Feng
Mohammad Din, Shahrulnizahani
author_sort Gooi, Wen Pin
title Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement
title_short Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement
title_full Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement
title_fullStr Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement
title_full_unstemmed Performance comparison for on-chip 3D ECT using peripheral and distributed electrode arrangement
title_sort performance comparison for on-chip 3d ect using peripheral and distributed electrode arrangement
publisher Springer Science and Business Media Deutschland GmbH
publishDate 2022
url http://eprints.utm.my/id/eprint/100756/
http://dx.doi.org/10.1007/978-981-19-3923-5_64
_version_ 1768006575891415040
score 13.159267